CHAPTER 8 USB FUNCTION
User’s Manual U12978EJ3V0UD
105
Figure 8-7. Configuration of Transmit Data Bank 1 (Buffer 1)
Data area (8 bytes)
USBPO
W address
ID area
USBPOB address
USBTD1
Symbol
07H
06H
05H
04H
03H
02H
01H
USBT10
USBT11
USBT12
USBT13
USBT14
USBT15
USBT16
USBT17
30H
00H
31H
32H
33H
34H
35H
36H
37H
38H
The operation during transmission appears as follows.
8th byte
1st byte
USBT00
USBT07
USBT10
USBT17
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
IN
DATA0
ACK
Packet from host controller
Response packet
8th byte
1st byte
USBT00
USBT07
USBT10
USBT17
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
IN
DATA1
ACK
Data is read according to the data sequence in the control read data stage and is transmitted to the host. In the
DATA0 sequence, the values saved in USBT00 to USBT07 are transmitted in sequence to the host. In the