Chapter 1 MAINTENANCE SERVICES
1-44
NWA-033627-001 Rev.4.0
95ch1001.fm
VoIP LOG COLLECTION
(2) To confirm whether the call logs is collected in the CPU or to clear logs, do the following
programming.
DESCRIPTION
DATA
Specify the stop bit for the RS port.
NOTE:
When using CPU RS-232C port for
PCPro, set the default.
•
(1)
(2)
Y=04
0: Unit01 Port1
1: Unit01 Port2
0 : 1-Stop bit
1 : 2-Stop bit
Specify the DTR signal sent to terminal for the
RS port.
NOTE:
When using CPU RS-232C port for
PCPro, set the default.
•
(1)
(2)
Y=05
0: Unit01 Port1
1: Unit01 Port2
0 : Low
1 : High
Specify the RTS signal sent to terminal for the
RS port.
NOTE:
When using CPU RS-232C port for
PCPro, set the default.
•
(1)
(2)
Y=06
0: Unit01 Port1
1: Unit01 Port2
0 : Low
1 : High
Specify the data speed of the RS port.
NOTE:
When you communicate with CPU
built-in modem, be sure to set the
data speed of RS1 port as 4800 bps
or more (1200 bps and 2400 bps are
not available).
•
(1)
(2)
Y=08
0: Unit01 Port1
1: Unit01 Port2
1
: 1200 bps
2
: 2400 bps
3
: 4800 bps
4
: 9600 bps
5
: 19200 bps
NONE : 9600 bps
DESCRIPTION
DATA
Display the call logs
that
are collected in the
CPU or clear the logs.
•
(1)
(2)
Y=6
01: Display of call log collection/log clear
0
: Logs are not collected
1
: Logs are collected
CCC: Log clear
B
CM40
END
START
CMEA
END
JULY/17/2009