Chapter 2 TROUBLESHOOTING
2-36
NWA-033627-001 Rev.4.0
95ch2001.fm
FAULT INFORMATION DISPLAY
Remedial Action on Each LED Status
BLADE
NAME
LED STATUS
FAULT
CONTENT
REMEDIAL ACTION
CD-CCTA
(CCT)
LIVE LED is not
flashing at 120
IPM
Abnormal operation of
CCT blade
Confirm the programming data:
CM05 Y=0.
Check to see if the cable is correctly
connected.
If the fault cannot be cleared,
replace the blade.
CD-4LCA/
8LCA (LC)
LIVE LED is not
flashing at 120
IPM
Abnormal operation of
LC blade
Confirm the programming data:
CM05 Y=0.
Check to see if the cable is correctly
connected.
If the fault cannot be cleared,
replace the blade.
CD-8DLCA/
16DLCA
(DLC)
LIVE LED is not
flashing at 120
IPM
Abnormal operation of
DLC blade
Confirm the programming data:
CM05 Y=0.
Check to see if the cable is correctly
connected.
If the fault cannot be cleared,
replace the blade.
CD-4CSIB
(CSI)
LIVE LED is not
flashing at 120
IPM
Abnormal operation of
CSI blade
Confirm the programming data:
CM05 Y=0.
Check to see if the cable is correctly
connected.
If the fault cannot be cleared,
replace the blade.
CD-4CSIB-A
(CSI)
LIVE LED is not
flashing at 120
IPM
Abnormal operation of
CSI blade
Confirm the programming data:
CM05 Y=0.
Check to see if the cable is correctly
connected.
If the fault cannot be cleared,
replace the blade.
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
APRIL/16/2010