Chapter 1 MAINTENANCE SERVICES
1-15
NWA-033627-001 Rev.4.0
95ch1001.fm
FAULT MESSAGE
External Alarm Display Panel
[8300R3 software required]
NOTE:
Setting of MJ/MN alarm of Fault Occurrence and Restoration is already programmed.
Operating Procedure
To Display Fault Messages using PCPro
For details, refer to PC Programming Manual.
DESCRIPTION
DATA
Select the external alarm kind.
•
(1)
(2)
Y=00
312, 313: External Relay Interface of CPU
blade
38XX
XX
: 01-02: Fault Information
01
: MJ Alarm
02
: MN Alarm
NONE : No Data
NOTE:
When connecting the RELAY port (Built-in CPU blade) and the MJ/MN lamp of Alarm
Display Panel, the first data must corresponding between the RELAY port and the Circuit
number assigned by CM44 Y=00. For detail of connecting the Alarm Display Panel, refer
to the System Hardware Manual.
• ERELAY port (EXCNT1) 1st data=312
• ERELAY port (EXCNT2) 1st data=313
Select the external relay control for MJ alarm.
(1)
(2)
912
0 : Relay OFF (External alarm is MJ
alarm/Relay ON (Clear the external
alarm (MJ))
1 : Relay ON (External alarm is MJ
alarm/Relay OFF (Clear the external
alarm (MJ))
START
CM44
CM08
END