Alarm
No.
Type
Re-
port
Name
Content of
Alarm
Cause
Action
Recovery
Alarm
Status
3
2
0
Connec-
tion fault
between
CPU and
other
PKGs.
The error occur-
red when com-
municating with
the package.
When the pack-
age is broken, it
recognizes it as
a communica-
tion fault.
1.
The unit is not
completely in-
serted.
2.
The power-
supply voltage
of the system
is outside rat-
ings.
3.
The equip-
ment that gen-
erates the
noise in the
same power
supply system
as the power
supply origin
of the system
is connected,
and it malfunc-
tions because
of the power
supply noise.
4.
The equip-
ment to which
it is adjacent
to of a main
device, and
has put out
the radiation
noise exists,
and it malfunc-
tions because
of the radia-
tion noise.
5.
The chassis is
not properly
grounded.
1.
Please insert
the unit firmly.
2.
The power-
supply voltage
must use an-
other power
supply when is
in the range of
ratings or
measuring
with the volt-
meter, and de-
viating from
the rated
range.
3.
Please use the
power supply
besides the
equipment
with the possi-
bility of the
noise source.
4.
Please sepa-
rate as much
as possible
and use a
main device
from the
equipment by
which you
seem may
generate the
radiation
noise.
5.
Please ground
the chassis
correctly.
When unit is
confirmed,
the error is
recovered.
ERR
REC
4
2
0
PKG S/W
Download
Error
The unit pro-
gram could not
be downloaded
normally.
The unit could
not able to be
started normal-
ly.
1.
The package
software is not
stored in the
downloaded
USB memory.
2.
The stored
package soft-
ware is illegal.
Package infor-
mation that
was installed
before re-
mains.
1.
Delete slot in-
formation that
corresponds
by Program
90-05-01 to
delete pack-
age informa-
tion that was
installed be-
fore.
2.
There is a
possibility that
the unit pro-
gram is broken
though an ex-
ternal factor of
the noise etc.
is thought.
3.
Please load in-
to the USB
memory and
try again when
you back up
the unit pro-
gram.
4.
Please Check
with maker on
uncertain
points.
Please ex-
change units,
though it is
likely to re-
store by
mounting the
unit again.
When the unit
program is
normally
downloaded,
the error is
recovered.
ERR
REC
ISSUE 3.01
SL1000/SL1100
Programming Manual
2-559
Program
90
Summary of Contents for SL1100
Page 1: ...Programming Manual A50 031167 002 EU ISSUE 3 01 Dec 2012 ...
Page 57: ...Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 35 Program 10 ...
Page 77: ...Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 55 Program 10 ...
Page 213: ...Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 191 Program 20 ...
Page 309: ...Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 287 Program 22 ...
Page 455: ...Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 433 Program 47 ...
Page 475: ...Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 453 Program 47 ...
Page 519: ...Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 497 Program 82 ...
Page 549: ...Feature Cross Reference None ISSUE 3 01 SL1000 SL1100 Programming Manual 2 527 Program 84 ...
Page 664: ...MEMO SL1000 SL1100 ISSUE 3 01 2 642 Program 93 System Information Program 93 ...
Page 665: ...MEMO ISSUE 3 01 SL1000 SL1100 Programming Manual 2 643 ...
Page 666: ...Programming Manual NEC Corporation ISSUE 3 01 ...