2. Confirmation of Unit Setup
Make sure that all the disk drives are started ( READY LEDs lit) and the POWER LEDs on the front
faces of both the Disk Array Unit and the Disk Enclosure are lit. Also make sure that the SVP/DIR
LED on the rear face of the Disk Array Unit blinks.
Then start the Maintenance PC according to Section 1.2.
2.1 Confirmation of FC Port Configuration
Select [1.Status]
→
[2..Control Port Status] to confirm the settings of FC Port Configuration.
When WWN is not defined
When WWN is defined
This function displays the FC Port status. The displayed items are as follows:
Port
Port name (setting value)
Host Type
Host type (setting value)
Link Attach
Setting value for Topology of Link
Switch
Setting value for Switch
Data Rate
Setting value for Data Rate on FC Link