S-156
(66) SOFT SWITCH: #64
• Bit 6: If this bit set to “1”, Machine does not print a RX error report if no Fax signal from
the other party is detected.
• Bit 5: Prevents user to change PPS if this bit set to “0”.
Bit
No.
Designation
Function
Initial
Setting
Bit HEX
8
Reserved
Reserved
0
1
7
Reserved Reserved
0
6
Print RX error report
on RX side if no FAX
signal is detected
0: No
1: Yes
0
5
10 PPS & 20 PPS
selectable by user
0: No
1: Yes
1
4
Reserved 0
0
3
Reserved 0
2
Reserved 0
1
Reserved 0