S-45
(10) Initial user data
• Various settings for the machine’s user data can be specified.
1. Date & Time
2. USER FAX No.
• User fax number is set to TSI (Transmitting Station Identification), CSI (Called Subscriber
Identification) during communication. A symbol is printed on header and Status list, but
only figure is set to TSI, CSI signal. This is checked with the communication permission
ID registered at destination station in case of Closed network.
• Max. 20 digits. The characters which can be inputted are “numbers from 0 to 9”,
“Space”, “+” and “-”
3. User name
• The User Name is used for the indication of destination station at the time of the commu-
nication between same models.
• Maximum 32 digits character can be inputted.
No.
Indication on LCD
1
DATE&TIME
2
USER FAX No.
9
USER NAME
Setting value
Description
Hour
00 to 23
Minute
00 to 59
Year
00 to 99 (2000 to 2099 will be meant)
Month
01 to 12
Day
01 to 28, 29, 30, 31
Time Zone
-12 hour to +12hour, interval: 30 minute.