T-36
(11) Printer system: Foggy background
<Typical Faulty Image>
<Troubleshooting Procedures>
(12) Printer system: Blank streaks or bands
<Typical Faulty Images>
<Troubleshooting Procedures>
Step
Check
Result
Action
1
Is PC Drum scratchy?
YES Replace Drum Cartridge.
2
Is developing bias contact terminal in good
contact with the mating part?
NO
Clean contact terminal or
check terminal position.
3
Is PH window dirty?
YES Clean.
4
Is the problem eliminated after checks have
been made up to step 3?
NO
Replace High Voltage Unit
(HV1).
Replace Controller/Mechani-
cal Control Board (PWB-P).
Step
Check
Result
Action
1
Is Image Transfer Roller dented, scratchy, or
dirty?
YES Replace Image Transfer
Roller.
2
Is PC Drum scratchy or dirty?
YES Replace Drum Cartridge.
3
Is Fusing Roller scratchy or dirty?
YES Replace Fusing Unit (Fusing
Roller).
4
Is PH window dirty?
YES Clean.
5
Is the problem eliminated after checks have
been made up to step 4?
NO
Replace Controller/Mechani-
cal Control Board (PWB-P).
4011T004AA
4011T015AA
4011T020AA