- 38 -
5. Troubleshooting
5-1. Troubleshooting
•
Error message is displayed at boot
Refer to the user's guide of CPU Blade for details of error messages.
If you feel the Mezzanine slot where this product is attached is the cause of the error, please check the
following items;
●
When Option ROM is not expanded,
→
Refer to the user's guide of CPU Blade to disable the Option Rom whose function is not in use.
●
When the error occurred on the Mezzanine slot where this product is attached,
- Please connect correctly this product again.
If the error message is displayed at boot even when all the above items are
confirmed, shut down the CPU Blade, connect the product to other Mezzanine
slot, reboot the CPU Blade, and perform the self-diagnostic program POST. If
POST ends normally, the CPU Blade may be defective. Please contact your
retailer or service center for repair.
•
This product does not work properly.
If your operating system or applications do not operate correctly after installing this product, please
check the following items, and please refer to the user's guide of the CPU Blade together.
●
Is the driver for the Fibre Channel Controller installed? Is the product installed in the CPU Blade
correctly?
- Please refer to the user's guide of the CPU Blade.
●
Are all Fibre Channel cables and power cords connected correctly?
- Please connect correctly this product again.
●
Is the WWPN setting correct if you have connected this product to a Fibre Channel device which
uses WWPN?
- Confirm that the lower 12 figures of WWPN match the IEEE address.
●
Is the FC through card or FC switch module setting (FC link speed, topology, etc.) correct for the
connected FC device?
- Please refer to the user's guide of the FC through card or FC switch module.
●
Is the location of the Mezzanine slot and SFP module and the FC through card or the FC switch
module proper?
- Please refer to the user's guide of the CPU Blade and Blade Enclosure and FC through card or
FC switch module.
If the CPU Blade does not work correctly even when all the above items are
confirmed, shut down the CPU Blade, disconnect the product, reboot the CPU
Blade, and perform the self-diagnostic program POST. If POST ends normally, this
product may be defective. Please contact your retailer or service center for repair.
Notice
Notice