38
2-2. Linux
1.
Enter the following command to check the property of RAID Controller.
# raidcmd property –tg=rc –c=C <ENTER>
“C” is the number of the RAID Controller. Following command is the example
when the number of RAID Controller is “1”.
# raidcmd property –tg=rc –c=1 <ENTER>
2.
The property of the RAID Controller is displayed. If the battery status is displayed
“Normal”, the battery is connected surely.
RAID Controller #1
ID
: 0
Vendor
: LSI Corporation
Model
: MegaRAID SAS 8708EM2 (xxxMB)
Firmware Version
: 1.xx.xx-xxxx
Cache Size
: xxxMB
Battery Status
: Normal
Rebuild Priority
: Low
Consistency Check Priority
: Low
Patrol Read
: Enable
Patrol Read Priority
: Low
Buzzer Setting
: Disable
Check
Indicates the status of the battery installed in the RAID Controller.
Three possible status are as follows:
・
Normal: Indicates that the battery can be used normally.
・
Warning: Indicates that the battery cannot be used normally due to some reason.
・
Not Present: Indicates that no battery is installed in the RAID Controller.
Summary of Contents for N8103-123