1. Installing Internal Optional Devices
Express5800/R120d-2M User’s Guide
67
Chapter 2 Preparations
1.13.6
Replacement / Removal
To remove DIMM, reverse the installation procedure.
Be sure to install dummy cover to the slots from where DIMMs are removed.
Important Failing to install dummy cover to vacant slot may cause malfunction of the
server due to insufficient cooling effect.
Note
When removing a defective DIMM, check error messages displayed at POST or
NEC ESMPRO and check the DIMM socket where the defective DIMM is installed.
Take the steps below after replacing or removing DIMMs.
1. Confirm that no error messages are displayed on POST. If any error message is displayed, refer to
Chapter 3 (1. Post Error Message)
in "
Maintenance Guide
".
2. Run BIOS Setup Utility, select
Memory Configuration
from the
Advanced
menu, and then
specify
Yes
for
Memory Retest
. After that, select
Save Changes and Exit
to reboot.
3. Set the size of Paging File to the recommended value (Total memory size x 1.5) or more.
If using a Windows OS, refer to
Chapter 1 (7.1 Specifying Memory Dump Settings (Debug
Information))
in "
Installation Guide (Windows)
".
For other OS, follow the manual of the OS.