1. Installing Internal Optional Devices
Express5800/R120d-2M User’s Guide
66
Chapter 2 Preparations
1.13.5
Installation
Install a DIMM by using the following procedure.
1.
Refer to steps 1 to 6 in Chapter 2 (
1.3 Overview of Installation and Removal
) for preparations.
2.
Open levers on left and right sides of DIMM slot, and remove the dummy cover.
Note
Keep the removed dummy cover for future use.
3.
Push the DIMM straight into the socket.
When a DIMM is inserted into the
socket, the lever automatically closes.
Important
•
Make sure the orientation of the DIMM. The DIMM has a notch, preventing
being incorrectly inserted.
•
Do not apply too much pressure when you push a DIMM into the socket.
Doing so can damage the socket or terminal part.
4.
Continue to install or remove internal optional devices, mount and connect the server, and turn it on.
5.
Confirm that no error messages are displayed in POST screen.
If any error messages are displayed, refer to
Chapter 3 (1. POST Error Message) in "Maintenance
Guide
".
6.
Run BIOS Setup Utility and select
Memory Configuration
and then
Memory Information
from the
Advanced
menu. Make sure the capacity of added DIMM is displayed properly.
Refer to
Chapter 2 (1. System BIOS) in "Maintenance Guide"
.
7.
Select
Memory Configuration
from the
Advanced
menu, and then specify
Yes
for
Memory Retest
.
After that, select
Save Changes and Exit
to reboot.
8.
Set the size of Paging File to the recommended value (Total memory size x 1.5) or more.
If using a Windows OS, refer to
Chapter 1 (7.1 Specifying Memory Dump Settings (Debug
Information)) in "Installation Guide (Windows)"
.
For other OS, follow the manual of the OS.
Key slot
Key