background image

NEC Display Solutions

Video Wall Installation Guide

Additional PC-less advanced calibration capabilities

Display Wall Calibrator application high-end adjustment capabilities

Out of the Box Calibration

All displays are rigorously calibrated at a factory level for gamma, RGB, intensity, white 

point and uniformity to their native settings.  Calibration should not be needed out of the 

box if these are the settings that are needed for this particular installation.

PC-less display Self-Calibration

Through self-calibration, each monitor adjusts its settings according to the factory 

calibrated LUT, managed by the onboard SpectraView engine. PC-less calibration uses 

an MDSVSENSOR3 (located in the KT-LFD-CC2 Color Calibration Kit) directly connected to 

the dedicated monitor’s USB interface.

Connect the MDSVSENSOR3 to the display monitor’s USB1 (SENSOR) interface.

Menu:

 PICTURE  >  SPECTRAVIEW ENGINE  >  CALIBRATION  >  SET STAND-ALONE 

CALIBRATION  >  SELF CALIBRATION  >  SET

Note:

 For proper handling, this feature is recommended for video walls of up to 3x3 

displays, depending on accessibility. For most efficient and better overall calibration, 

larger video walls should be calibrated via the PC-based 

Display Wall Calibrator

 

application. 

In addition to the extensive calibration capabilities, two new high-end adjustment features lift the video wall calibration result to a new outstandingly high level. For further details please 

refer to the Display Wall Calibrator application users manual.

Corner Uniformity Correction

To perform the corner color matching on a single monitor.

PC-less White Copy function

Using the self-calibration feature, settings from a reference display are copied to each 

dedicated display in the video wall. Connect a MDSVSENSOR3 to the USB interface of the 

display to be adjusted. Using the sensor, measure a white test pattern on the reference 

display to readjust the display calibration.

Connect the MDSVSENSOR3 into the USB1 (SENSOR) interface of the display to be 

adjusted.

Place the sensor on the reference monitor showing a seeing a generated white test 

pattern.  Note that an external source is necessary for this.

Menu:

 PICTURE  >  SPECTRAVIEW ENGINE  >  CALIBRATION  >  SET STAND-ALONE 

CALIBRATION  >  WHITE COPY  >  SET

Note:

 To perform White Copy, self-calibration must be completed beforehand. For proper 

handling, this feature is recommended for video walls of up to 3x3 displays, depending 

on accessibility. For most efficient and better overall calibration, larger video walls should 

be calibrated via the PC-based 

Display Wall Calibrator

 application.

Uniformity Correction

To perform internal screen uniformity on a display, up to 10x10 measurement points can 

be defined within one monitor.

USB1 SENSOR