-Advanced option
IR CONTROL
TILE MATRIX
HEAT STATUS
POWER ON DELAY
DATE & TIME
SCHEDULE
ADVANCED
OPTION RESET
Adjusts the delay time from "standby" to "power on"
mode.
"POWER ON DELAY" can be set between
0 and 50 sec.
Sets the current date and time for internal clock.
Date and time has to be set in order for the
"SCHEDULE" function to work properly.
The "TILE MATRIX" feature allows one image to be
displayed on multiple screens. This feature can be used
with up to 25 monitors. (5 horizontal x 5 vertical)
Using the Tile Matrix function requires the PC output signal
to be sent through a distribution amplifier to each
individual monitor.
H MONITORS: Selects the number of horizontal displays.
V MONITORS: Selects the number of vertical displays.
POSITION: Selects a position to expand the screen.
TILE COMP: Works in tandem with "TILE MATRIX" to
compensate for the width of the tiled bezels in order to
accurately display the image.
ENABLE: Select "YES", to expand the signal to the
selected settings.
PIP, POP, SIDE by SIDE, STILL and DYNAMIC zoom mode
will be disabled when the "TILE MATRIX" is activated.
Note:
LCD4010 and LCD4610 Displays can NOT be
used together with the Tile Matrix function.
Displays status of COOLING FAN, BRIGHTNESS and
TEMPERATURE.
COOLING FAN activates when the inside temperature
exceeds highest recommended operating temperature
BRIGHTNESS decreases when inside temperature
exceeds highest recommended operating temperature
with cooling fan running. In this case a warning is
displayed on the screen.
Programs the monitor's
working schedule.
Sets the hour and day of the
week when the monitor
powers on or off. Also sets
the input port.
Select "EXIT" to set schedule.
(see "NOTE 3" on page 28
for further information)
Selecting ADVANCED OPTION RESET allows you to
reset all OSM settings from the ADVANCED OPTION
settings, except for DATE & TIME, and SCHEDULE.
Select "YES" and press "SET" button to restore the
factory preset data.
Press "EXIT" button to cancel and then return the
previous menu.
Selects the infra-red wireless remote controllers mode with
using the RS-232C daisy chain.
The item in this menu will become effective by pressing
"SET" button on the selected item.
NORMAL: The monitor will be controlled normally by
wireless remote controller.
PRIMARY: Set "PRIMARY" at the head of the daisy
chained monitors by RS-232C.
SECONDARY: Set "SECONDARY" after 2nd daisy
chained monitor.
LOCK: Disable the monitor control by infra-red wireless
remote controller.
Keep pressing "DISPLAY" button for 5 or more seconds,
this setting will return to "NORMAL".
See "NOTE 2" on page 28
EXIT
SET
:RETURN
:SET
MENU
:EXIT MENU
IR CONTROL
:SEL
NORMAL
PRIMARY
SECONDARY
LOCK
EXIT
:RETURN
MENU
:EXIT MENU
TILE MATRIX
:SEL
H MONITORS
V MONITORS
POSITION
TILE COMP
ENABLE
1
1
1
YES / NO
YES / NO
+ -: ADJ
EXIT
:RETURN
MENU
:EXIT MENU
POWER ON DELAY
3 SEC.
EXIT
:RETURN
MENU
:EXIT MENU
DATE & TIME
:SEL
YEAR
MONTH
DAY
TIME
DAYLIGHT SAVING YES / NO
CURRENT DATE TIME
JAN. 01. 2004 00 : 00 : 00
2004
JANUARY
01
00
: 00
:SET
ADVANCED OPTION
MONITOR ID
IR CONTROL
TILE MATRIX
HEAT STATUS
POWER ON DELAY
DATE & TIME
SCHEDULE
ADVANCED OPTION RESET
:SEL
SET
:NEXT
EXIT
:RETURN
MENU
:EXIT MENU
ADVANCED OPTION
MONITOR ID
IR CONTROL
TILE MATRIX
HEAT STATUS
POWER ON DELAY
DATE & TIME
SCHEDULE
ADVANCED OPTION RESET
:SEL
SET
:NEXT
EXIT
:RETURN
MENU
:EXIT MENU
ADVANCED OPTION
MONITOR ID
IR CONTROL
TILE MATRIX
HEAT STATUS
POWER ON DELAY
DATE & TIME
SCHEDULE
ADVANCED OPTION RESET
:SEL
SET
:NEXT
EXIT
:RETURN
MENU
:EXIT MENU
ADVANCED OPTION
MONITOR ID
IR CONTROL
TILE MATRIX
HEAT STATUS
POWER ON DELAY
DATE & TIME
SCHEDULE
ADVANCED OPTION RESET
:SEL
SET
:NEXT
EXIT
:RETURN
MENU
:EXIT MENU
ADVANCED OPTION
MONITOR ID
IR CONTROL
TILE MATRIX
HEAT STATUS
POWER ON DELAY
DATE & TIME
SCHEDULE
ADVANCED OPTION RESET
:SEL
SET
:NEXT
EXIT
:RETURN
MENU
:EXIT MENU
ADVANCED OPTION
MONITOR ID
IR CONTROL
TILE MATRIX
HEAT STATUS
POWER ON DELAY
DATE & TIME
SCHEDULE
ADVANCED OPTION RESET
:SEL
SET
:NEXT
EXIT
:RETURN
MENU
:EXIT MENU
ADVANCED OPTION
MONITOR ID
IR CONTROL
TILE MATRIX
HEAT STATUS
POWER ON DELAY
DATE & TIME
SCHEDULE
ADVANCED OPTION RESET
:SEL
SET
:NEXT
EXIT
:RETURN
MENU
:EXIT MENU
ADVANCED OPTION RESET
EXIT
:RETURN
MENU
:EXIT MENU
NO
YES
:SEL
EXIT
:RETURN
MENU
:EXIT MENU
HEAT STATUS
STATUS
COOLING FAN1 ON
COOLING FAN2 ON
BRIGHTNESS NORMAL
TEMPERATURE
SENSOR 1 0.0 C / 32.0 F
SENSOR 2 0.0 C / 32.0 F
EXIT
:RETURN
MENU
:EXIT MENU
SCHEDULE
TODAY THURSDAY, JAN. 01. 2004 10:00
+ - :SEL
MON TUE WED THU FRI SAT SUN EVERY WEEK
ON
1 0 : 0 0
OFF
1 7 : 0 0
EVERY DAY
INPUT
RGB 1
MON TUE WED THU FRI SAT SUN EVERY WEEK
ON
1 1 : 0 0
OFF
1 8 : 0 0
EVERY DAY
INPUT
RGB 1
1
2
MON TUE WED THU FRI SAT SUN EVERY WEEK
ON
0 0 : 0 0
OFF
1 0 : 0 0
EVERY DAY
INPUT
RGB 1
3
MON TUE WED THU FRI SAT SUN EVERY WEEK
ON
0 0 : 0 0
OFF
1 0 : 0 0
EVERY DAY
INPUT
RGB 1
4
SET
: SET
+ -:ADJ
+ -:ADJ
SET