6-2
1-3. Operation
- The operation should be performed according to the screen message.
- When the message of “Please set Vsync to 42Hz.” is displayed, set the signal generator to the signal
with vertical synchronization frequency of 42Hz. When the message of “Please set Vsync to over 55Hz.”
is displayed, set the signal generator to the signal whose vertical synchronization frequency is between
55Hz and 25kHz.
-
The message of “Normally Complete” means that writing of EDID data or PnP inspection completed normally.
The message of “Error” means that writing of EDID data or PnP inspection finished incorrectly.
- When the PnP inspection is completed, read EDID data would be displayed. And if the read EDID data
differed from the original EDID data, the different bytes would be displayed in red.
- For the details of error, see the messages displayed at the bottom right of the screen. The meaning of
the messages is shown on section 4.
- After writing of EDID data or inspection of DDC2B, monitor can not be communicated by DDC1. In that
case, turn off and on the monitor again, which will make the DDC1 communication test possible.
- Make sure that fixture’s LED flashes on and off before writing EDID data, inspecting DDC1 and DDC2B.
If the fixture’s LED does not flash on and off, turn off and turn on the monitor and the fixture.
1-4. Error Messages
- Start Bit Error
This message is displayed when the start bit is not “H” while sending data from PC to MPU on the
fixture. This error will be caused by noise etc. on the line.
- Command Error
This message is displayed when the different command is sent from PC to MPU on the fixture.
- Hardware Error
This message means that the PC does not recognize ACK command sent from the MPU on the fixture.
- File Open Error
This message means that the input EDID file name was wrong.
- Command line Switch Error
This message means that the input communication command is incorrect.
- Parity Error
This message is displayed when the MPU on the fixture recognized the parity bit is incorrect. This error
can be caused by noise etc. on the line.
- EDID Data Error
This message is displayed when the null bit is not detected in EDID data read by DDC1 communication.
- EDID Data Sort Error
This message is displayed when the header code is not detected in EDID data read by DDC1 communication.
- Time Out Error
This message is displayed when the PC does not recognize ACK commands sent from MPU within
10m sec after the PC had sent communication command or EDID data. If this error occurs, check the
connection on PC, fixture and monitor.
Summary of Contents for MultiSync FP1370
Page 13: ...4 4 REMARK SYMBOL Mount the EMF PWB 121E REMARK SYMBOL Clamp the connector ...
Page 14: ...4 5 REMARK SYMBOL COIL FORMING UPPER SIDE REMARK SYMBOL COIL FORMING LOWER SIDE ...
Page 23: ...4 14 REMARK SYMBOL REMARK SYMBOL Clamp CN CA CN CC and CN D with CLAMPER WIRE ...
Page 26: ...4 17 REMARK SYMBOL Clamp the wires SAFETY REMARK SYMBOL Clamp the wires CN ASD CN AF 21 ...
Page 80: ...5 51 Fig 3 11 CONV PWB Fig 3 12 EMF PWB CN EMF CN LL CN RR CNEM CN CA CN D CN CCB HS8N1 ...
Page 143: ...8 18 15V 80V AFC D FOCUS Fig 3 1 HIGH VOLTAGE CIRCUIT AND PROTECTOR CIRCUIT ...
Page 260: ...10 1 ...
Page 261: ...10 2 ...
Page 262: ...10 3 ...
Page 263: ...10 4 ...
Page 264: ...10 5 ...
Page 266: ...for Human Potential ...
Page 267: ......
Page 268: ......
Page 269: ......
Page 270: ......
Page 271: ......
Page 272: ......
Page 273: ......
Page 274: ......
Page 275: ......
Page 276: ......
Page 277: ......
Page 278: ......
Page 279: ......
Page 280: ......
Page 281: ......
Page 282: ......
Page 283: ......
Page 284: ......
Page 285: ......
Page 286: ......