6-4. Cut off Adjustment
Signal: No.23 (1600*1200@85Hz) All black
1) Receive signal 23 All black
2) Open Menu (S), TAG8 "SUB BIAS" and push
“
RESET
”
SW.
Note: Do not touch a front panel key and do not come out from
“
SUB BIAS
”
since a picture can not be seen.
3) Connect the DVM with a high voltage probe at TP-G2 on the CRT PWB and adjust SCREEN
VR to obtain 700 Vdc
±
5 Vdc. (Use a high voltmeter whose maximum voltage is more than 1.5kV and
input resistance is more than 1000 M
Ω
.)
4) Set 00 channel x, y, Y modes of color analyzer CA-100 and make sure that the following values are preset.
x = 0.273
y = 0.300
Y = 0.2 cd/
㎡
5) Set analyzer mode at color analyzer.
6) Open Menu (S), TAG8 " SUB BIAS " and adjust until raster appears with “+” and “-“ SW.
The color that appears first is the reference color.
Adjust “+”,”-“SW so that its color analyzer indicated value is 20-80.
If color analyzer does not indicate 20-80, adjust “SUB BIAS” 255 and go to (7).
Then reference color is anything OK.
7) Open Menu (S), TAG8 and adjust the reference color bias so that its analyzer indicated value is 90-110.
8) Open Menu (S), TAG8 and adjust the other color biases so that its analyzer indicated value is 90-110.
9) When the indicated value of the reference color is over 110, repeat steps (7) to (8) so that it is 90-110.
10) Close menu.
6-5. Contrast Tracking Adjustment Signal: No.23 (1600*1200@85Hz)
Window Pattern (H: 33% V:33%)
1) Receive Signal 23.
2) Open Menu (S), TAG8
“
CONT MAX/MIN
”
. Adjust "+" SW so that the contrast is max.
3) Setting modes x, y, Y at the color analyzer, measures the window color temperature. This
measurement determines x=x1, y=y1.
4) Open Menu (S), TAG8
“
CONT MAX/MIN
”
. Adjust "-" SW so that the contrast is min.
5) Measure the window color temperature. This measurement determines x=x2, y=y2.
6) Open Menu(S), TAG8
“
G BIAS
”
,
”
R BIAS
”
,
”
B BIAS
”
and make sure that the window color
temperature are the following values :
x2 = x1
±
0.003
y2 = y1
±
0.003
7) Open Menu (S), TAG8
“
CONT MAX/MIN
”
. Adjust "+" SW so that the contrast is max.
8) Measure the window color and confirm that the readings are the following values :
x1 = x2
±
0.003
y1 = y2
±
0.003.
If not, repeat items 3) to 8).
9) Push "EXIT" SW twice.
SAFTY
Summary of Contents for MultiSync FP1370
Page 13: ...4 4 REMARK SYMBOL Mount the EMF PWB 121E REMARK SYMBOL Clamp the connector ...
Page 14: ...4 5 REMARK SYMBOL COIL FORMING UPPER SIDE REMARK SYMBOL COIL FORMING LOWER SIDE ...
Page 23: ...4 14 REMARK SYMBOL REMARK SYMBOL Clamp CN CA CN CC and CN D with CLAMPER WIRE ...
Page 26: ...4 17 REMARK SYMBOL Clamp the wires SAFETY REMARK SYMBOL Clamp the wires CN ASD CN AF 21 ...
Page 80: ...5 51 Fig 3 11 CONV PWB Fig 3 12 EMF PWB CN EMF CN LL CN RR CNEM CN CA CN D CN CCB HS8N1 ...
Page 143: ...8 18 15V 80V AFC D FOCUS Fig 3 1 HIGH VOLTAGE CIRCUIT AND PROTECTOR CIRCUIT ...
Page 260: ...10 1 ...
Page 261: ...10 2 ...
Page 262: ...10 3 ...
Page 263: ...10 4 ...
Page 264: ...10 5 ...
Page 266: ...for Human Potential ...
Page 267: ......
Page 268: ......
Page 269: ......
Page 270: ......
Page 271: ......
Page 272: ......
Page 273: ......
Page 274: ......
Page 275: ......
Page 276: ......
Page 277: ......
Page 278: ......
Page 279: ......
Page 280: ......
Page 281: ......
Page 282: ......
Page 283: ......
Page 284: ......
Page 285: ......
Page 286: ......