5-16
b. Earth resistance testing
This testing should be carried out prior to the dielectric strength test.
The earth resistance should be 100m
Ω
or less when a current of 25A AC is carried between the earth
side of the cord and the metallic block that is used as a safety earth for the unit.
1.7.3 Dielectric Strength Test
To confirm the freedom from insulation breakdown, testing should be carried out under the conditions
specified below.
1) Measuring conditions
•
Measuring instrument : Dielectric strength tester (The specified voltage should be maintained
in the state that a current of 10mA is carried.)
•
Testing point
: Between the electrical circuit block and the exposed metallic block
(DVI connector)
Note: The electrical circuit block should mean the power input block (primary side). Testing should be
carried out under the condition that both poles of the power plug are short-circuited. (Where a 3-core
cord is used, the two poles other than the earth terminal should be short-circuited.)
2) Judgment standard
The freedom from insulation breakdown should be confirmed under the condition that the applied voltage
is maintained at 1500V AC (+0 to 50V) for one minute.
Even though the result of this testing is OK, such a condition should be regarded as unacceptable if there
is a leakage (flashing) around the section where the test voltage has been applied.
Summary of Contents for LCD2080UX - MultiSync - 20.1" LCD Monitor
Page 4: ...1 1 User s Manual 1 A Version MultiSync LCD2080UX TM ...
Page 30: ...1 27 2 B Version MultiSync LCD2080UX User s Manual ...
Page 439: ...SCHEMATIC DIAGRAM LCD2080UX MAIN PWB 1 14 10 1 ...
Page 440: ...SCHEMATIC DIAGRAM LCD2080UX MAIN PWB 2 14 10 2 ...
Page 441: ...SCHEMATIC DIAGRAM LCD2080UX MAIN PWB 3 14 10 3 ...
Page 442: ...SCHEMATIC DIAGRAM LCD2080UX MAIN PWB 4 14 10 4 ...
Page 443: ...SCHEMATIC DIAGRAM LCD2080UX MAIN PWB 5 14 10 5 ...
Page 444: ...SCHEMATIC DIAGRAM LCD2080UX MAIN PWB 6 14 10 6 ...
Page 445: ...SCHEMATIC DIAGRAM LCD2080UX MAIN PWB 7 14 10 7 ...
Page 446: ...SCHEMATIC DIAGRAM LCD2080UX MAIN PWB 8 14 10 8 ...
Page 447: ...SCHEMATIC DIAGRAM LCD2080UX MAIN PWB 9 14 10 9 ...
Page 448: ...SCHEMATIC DIAGRAM LCD2080UX MAIN PWB 10 14 10 10 ...
Page 449: ...SCHEMATIC DIAGRAM LCD2080UX MAIN PWB 11 14 10 11 ...
Page 450: ...SCHEMATIC DIAGRAM LCD2080UX MAIN PWB 12 14 10 12 ...
Page 451: ...SCHEMATIC DIAGRAM LCD2080UX MAIN PWB 13 14 10 13 ...
Page 452: ...SCHEMATIC DIAGRAM LCD2080UX MAIN PWB 14 14 10 14 ...
Page 453: ...SCHEMATIC DIAGRAM LCD2080UX POWER PWB 1 1 10 15 ...