background image

Welch Allyn Home

 

Blood Pressure Monitor
1500 Series

Directions for use

901042 Automated Blood Pressure System
RPM-BP100

Software version 1.X

Summary of Contents for Welch Allyn Home 1500 Series

Page 1: ...Welch Allyn Home Blood Pressure Monitor 1500 Series Directions for use 901042 Automated Blood Pressure System RPM BP100 Software version 1 X...

Page 2: ...by Welch Allyn is under license Software in this product is 2017 Welch Allyn or its vendors All rights are reserved The software is protected by United States of America copyright laws and internatio...

Page 3: ...warnings and cautions 8 Warnings and cautions 9 Contents list 14 Controls and indicators 15 Power options 17 Screen elements 18 Measuring blood pressure 21 Overview 21 Set up your equipment 22 Connec...

Page 4: ...and cuff 37 Troubleshooting 38 Problems and error messages 38 Technical alarms 38 Physiological alarms 42 Specifications 43 General radio compliance 45 Federal Communication Commission FCC Interferen...

Page 5: ...uscultation method This Directions for use contains important safety and care information and provides step by step instructions for using the monitor Read the manual thoroughly before using the monit...

Page 6: ...contraindicated for any person who is connected to a wearable or implantable electronic device or instrument such as a pacemaker or defibrillator This blood pressure monitor is not intended to be a di...

Page 7: ...entify conditions or practices that could lead to illness injury or death Caution The caution statements in this manual identify conditions or practices that could result in damage to the equipment or...

Page 8: ...Blood Pressure Monitor Shipping storing and environment symbols Relative humidity limits Recycle the product separate from other disposables Temperature limits Atmospheric air pressure Recycle Stacki...

Page 9: ...Directions for use 5 Blood pressure device and cuff symbols Artery marker Range Index edge Limb circumference Minimum Maximum Lot code Not made with natural rubber latex...

Page 10: ...ressure Monitor Miscellaneous symbols Type BF applied part Serial number Product Identifier Manufacturer Reorder number Model number Non ionizing electromagnetic radiation Global Trade Identification...

Page 11: ...ctions for use 7 IP22 Ingress protection the device is protected against solid foreign objects of 12 5mm and greater and against vertically falling water drops when ENCLOSURE is tilted up to 15 Blueto...

Page 12: ...ce you must familiarize yourself with all cautions with the steps to power up the device and with the sections of this Directions for use that pertain to your use of the device In addition to reviewin...

Page 13: ...ripheral arterial disease and users undergoing intravascular therapy or arterio venous shunt or people who received a mastectomy Consult your doctor prior to using the unit if you suffer from any of t...

Page 14: ...air from the cuff Loosen and remove the cuff from your arm WARNING Injury risk On the rare occasion of a fault causing the cuff to remain fully inflated during measurement open the cuff immediately Pr...

Page 15: ...e batteries adapter and the user simultaneously WARNING Injury risk Do not use the unit if you are allergic to polyester or synthetic materials WARNING Injury risk Excessive tube lengths could cause s...

Page 16: ...e while using the device WARNING Injury risk Use only accessories approved by the manufacturer Using unapproved accessories might cause damage to the unit and injure users WARNING Injury risk No modif...

Page 17: ...me time Caution To avoid measurement errors avoid taking blood pressure measurements near a strong electromagnetic field radiated interference signal or electrical fast transient burst signal Caution...

Page 18: ...eries Directions for use Quick reference guide Caution Do not attempt to repair the unit yourself if it malfunctions Only have repairs carried out by authorized service centers Caution Report any unex...

Page 19: ...y to upper arm to take a blood pressure measurement 2 Air tube Connects the cuff to the air connector plug 3 Air connector plug Air tube connects to the air connector plug 4 Power button Powers on the...

Page 20: ...ding and other pertinent information regarding the reading No Feature Description 1 Direct current power connection When used with an accessory power cord not included connects the monitor to a power...

Page 21: ...s The monitor is powered by one of two sources 4 AA alkaline batteries AC adapter 6v 1A not included Caution To get optimal performance and protect your monitor use only the correct batteries or the W...

Page 22: ...isplays the following systolic blood pressure mmHg diastolic blood pressure mmHg pulse rate bpm heart beat regular or irregular while acquiring blood pressure measurements excessive motion alert Bluet...

Page 23: ...ure mmHg measurement unit of the blood pressure Pulse in beats per minute Irregular heartbeat Monitor is detecting an irregular heartbeat during measurement Heart beat Monitor is detecting a heartbeat...

Page 24: ...ing out of range Either SYS 260mmHg or DIA 220mmHg The symbol may appear in either the SYS or DIA area of the screen Alarm priority Low an appears near the top of the screen Reading out of range Eithe...

Page 25: ...teries under normal circumstances To measure your blood pressure you need the following Blood pressure monitor with batteries inserted Blood pressure cuff D ring style for easy one handed adjustment B...

Page 26: ...lace the batteries when any of the following occurs The battery charge indicator indicates a low charge The display dims The display does not light up 1 Slide off the battery cover WARNING Injury risk...

Page 27: ...use 23 2 Install the batteries by matching the polarity as shown in the diagram 3 Replace the cover Connect the blood pressure air tube 1 Locate the air connector plug on the left side of the blood pr...

Page 28: ...air tube connector locks into place Listen for a click When the air tube connector is properly seated you cannot pull it off the air connector plug NoteYou may leave the air tube connected to the blo...

Page 29: ...ome application follow the pairing instructions presented in the application Contact your Remote Monitoring Solution provider or use the instructions that office provided to set up these communication...

Page 30: ...ul a steady symbol surrounded by a dotted line appears on the LCD screen If unsuccessful the appears Position the blood pressure cuff To achieve an accurate blood pressure reading follow these steps t...

Page 31: ...own over your hand It should appear on your arm as shown 3 Open the cuff to resize it as needed and slide it over your bare upper arm The bottom edge of the cuff should be 2 to 3 centimeters 0 8 to 1...

Page 32: ...rm but not too tight If you can insert just two fingers between the cuff and your arm the tightness is acceptable Start the measurement 1 Prepare yourself to take your blood pressure a Sit comfortably...

Page 33: ...pressure measurement The cuff inflates and tightens around your arm until it completes the measurement A vertical stack of segments appears onscreen to show increasing pressure in the cuff The heart...

Page 34: ...isplays the most recent record first as record 1 Each new measurement becomes record 1 and all other records move down the list for example 2 becomes 3 and so on You can store a maximum of 99 records...

Page 35: ...blood pressure device After 10 seconds of inactivity the device powers down If you press and release the Power button the device powers down After successful transfer the device powers off the Blueto...

Page 36: ...and forefinger on the grooved portion of the metal air tube connector and pull it back Do not twist the connector 2 Gently pull the air tube away from the monitor You can now store the monitor and the...

Page 37: ...ment of the heart rate or the number of times the heart beats per minute As the heart pushes blood through the arteries the arteries expand and contract with the flow of the blood Irregular heartbeat...

Page 38: ...nt from blood pressure on your other arm Use the same arm for blood pressure measurements Medication might affect your blood pressure The white coat effect might cause your blood pressure to be higher...

Page 39: ...smoking or drinking caffeinated beverages Taking a measurement while talking or moving your fingers Taking a measurement when you need to urinate Taking measurements in rapid succession Factors that p...

Page 40: ...6 Welch Allyn Home Blood Pressure Monitor and before taking a blood pressure measurement Sitting still during measurement Not talking during measurement Waiting at least 3 minutes between measurements...

Page 41: ...d shaking and dropping the monitor Avoid operating the monitor in dusty and unstable temperature environments Cleaning 1 Clean the monitor only when necessary with one of the following compatible clea...

Page 42: ...rror messages The device presents technical alarms and low priority physiological alarms Technical alarms occur when there is a device related error Physiological alarms occur when blood pressure meas...

Page 43: ...ws The cuff is not secure Readjust the cuff relax for a moment and then measure again E 02 shows The cuff is very tight Refasten the cuff and then measure again E 03 shows There is too much pressure i...

Page 44: ...on the arm and then measure again E 21 shows The measure ment is incorrect Relax for a moment and then measure again EE or E 19 shows Hardware error Measure again If the problem persists contact the...

Page 45: ...Directions for use 41 Visit www welchallynhome com for further assistance Problem Symptom Root cause Solution...

Page 46: ...ss and hold the Power button to reestablish Bluetooth connectivity Measure again If the problem persists contact your physician Alarm priority Low Out of range Either SYS 50mmHg or DIA 25mmHg The symb...

Page 47: ...0V 50 60Hz 400mA Output 6V 1A Power supply model number UE08WCP 06100SPA Display mode Digital LCD V A 68mm 90mm Measurement model Oscillometric testing mode Measurement range Rated cuff pressure 0mmHg...

Page 48: ...0 C Relative Humidity 10 RH 93 RH Atmospheric Pressure 50kPa to 106 kPa Circumference of the upper arm Part Number Cuff size Standard wide RPM BPACC 02 22cm to 42cm Approxim ately 9in to 17in Net Weig...

Page 49: ...This device must accept any interference received including interference that may cause undesired operation This equipment FCC ID OU9TMB1591 B has been tested and found to comply with the limits for a...

Page 50: ...guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipm...

Page 51: ...RF exposure requirements this device must be installed in a location where the antennas of the device will have a minimum distance of at least 20 cm from all persons Using higher gain antennas and typ...

Page 52: ...ause undesired operation of the device Cet appareil est conforme aux normes RSS exemptes de licence de l Industry Canada Son fonctionnement est soumis aux deux conditions suivantes 1 l appareil ne doi...

Page 53: ...ctions for use 49 r pertori e dans la table des sp cifications This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme la norme NMB 003 du Can...

Page 54: ...d General requirements User manual EN 1041 Medical equipment manufacturers to provide information General Requirements for Safety IEC 60601 1 A1 Medical electrical equipment Part 1 General requirement...

Page 55: ...ts Performance requirements and clinical investigation IEC 80601 2 30 Medical electrical equipment Part 2 30 Particular requirements for the basic safety and essential performance of automated non inv...

Page 56: ...IEC 62366 Medical devices Application of usability engineering to medical devices IEC 62366 IEC 60601 1 6 Medical electrical equipment Part 1 6 General requirements for basic safety and essential per...

Page 57: ...d shall start on the date of purchase The date of purchase is 1 the invoiced ship date if the device was purchased directly from Welch Allyn 2 the date specified during product registration 3 the date...

Page 58: ...y Shipping cost to return a device to a Welch Allyn service center is not included A service notification number must be obtained from Welch Allyn prior to returning any products or accessories to Wel...

Page 59: ...for use 55 Approved accessories Item Description RPM BPACC 02 D Ring Standard Wide Cuff 22 42cm RPM BPACC 04 RPM BP AC Adapter This adapter is an alternate power source for the blood pressure monitor...

Page 60: ...56 Welch Allyn Home Blood Pressure Monitor...

Page 61: ...cordless telephones and their base stations walkie talkies can affect this equipment and should be kept at least a distance d 3 3m away from the equipment Note As indicated in Table 6 of IEC 60601 1...

Page 62: ...is suitable for use in all establishments including domestic establishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purpo...

Page 63: ...discharge ESD IEC 61000 4 2 6 kV contact 8kV air 6 kV contact 8kV air Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at l...

Page 64: ...is recommended that the Welch Allyn Home Blood Pressure Monitor be powered from an uninterruptible power supply or a battery 40 UT 60 dip in UT for 5 cycles 40 UT 60 dip in UT for 5 cycles 70 UT 30 d...

Page 65: ...h an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Portable and mobile RF communications equipment should be used no closer to any part of the We...

Page 66: ...t power rating ofthe transmitter in watts W and d is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site surveya should...

Page 67: ...tically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which...

Page 68: ...Monitor can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the Welch Allyn Home Blood Pressure Mon...

Page 69: ...g of the transmitter in watts W according to the transmitter manufacturer Note 1 At 80 MHz and 800 MHz the separation distance for the higher frequency range applies Note 2 These guidelines may not ap...

Page 70: ......

Page 71: ......

Page 72: ...Welch Allyn Home Blood Pressure Monitor Model RPM BP100 726882 DIR 80022180 Ver A...

Reviews: