background image

SYSTEM CONFIGRATION GUIDE – 

NEC Express5800/T110j

 

NEC Corporation 

Revision 1.0 

– December 2018 

28

 

OS Support Matrix for PCI Cards and Embedded Controllers 

Part Number 

Product Name 

WS 

2

0

1

6

 

RH
EL
 7

.5

 

Embedded SATA non-RAID Controller 

 

Embedded SATA RAID Controller 



Embedded 1GbE NIC 

 

N8103-205 

RAID Controller (2GB, RAID 0/1/5/6) 

 

 

N8103-206 

RAID Controller (2GB, RAID 0/1, WT/WB) 

 

 

N8103-207 

RAID Controller (2GB, RAID 0/1/5/6, WT/WB) 

 

 

N8103-208 

RAID Controller (4GB, RAID 0/1/5/6) 

 

 

N8103-210 

RAID Controller (2GB, RAID 0/1, WT) 

 

 

N8103-211 

RAID Controller (2GB, RAID 0/1/5/6, WT) 

 

 

N8104-157 

Dual Port 10GBASE-T Adapter 

 

N8104-149 

10GBASE SFP+ Adapter (SFP+/2ch) 

 

N8103-184 

SAS Controller 

 



N8103-199 

SAS Controller 

 

N8104-151 

Dual Port 1000BASE-T Adapter 

 

N8104-150 

1000BASE-T Adapter 

 

Support

ed PCI cards and Installable Slots 

 

 

Slots 

Part Number 

Product Name 

#1 

#2 

#3 

#4 

N8103-205 

RAID Controller (2GB, RAID 0/1/5/6) 

(1) 

N8103-206 

RAID Controller (2GB, RAID 0/1, WT/WB) 

(1) 

N8103-207 

RAID Controller (2GB, RAID 0/1/5/6, WT/WB) 

(1) 

N8103-208 

RAID Controller (4GB, RAID 0/1/5/6) 

(1) 

N8103-210 

RAID Controller (2GB, RAID 0/1, WT) 

(1) 

N8103-211 

RAID Controller (2GB, RAID 0/1/5/6, WT) 

(1) 

N8104-157 

Dual Port 10GBASE-T Adapter 

(3) 

(4) 

(1) 

(2) 

N8104-149 

10GBASE SFP+ Adapter (SFP+/2ch) 

(2) 

(3) 

(1) 

N8103-184 

SAS Controller 

(1) 

(2) 

N8103-199 

SAS Controller 

(3) 

(1) 

(2) 

N8104-151 

Dual Port 1000BASE-T Adapter 

(2) 

(4) 

(1) 

(3) 

N8104-150 

1000BASE-T Adapter 

(2) 

(4) 

(1) 

(3) 

N8118-307 

Dual M.2 SATA Mount Kit 

(1) 

(2) 

(3) 

(4) 

N8117-01A 

Serial Port Adapter 

(2) 

(4) 

(1) 

(3) 

NOTE: 

 

The number between parentheses shows the population priority (recommendation). For example, install N8103-205 in the slot 
#4 and N8104-157 in the slot #1 when you have those cards. 

 

There are PCI slot limitations depending on the processor and operating system. Please refer to the following and be careful to 
choose a processor and PCI cards. 

Summary of Contents for Express5800/T110j

Page 1: ... Introduction This document contains product and configuration information that will enable you to configure your system The guide will ensure fast and proper configuration of your NEC Express5800 server December 28 2018 Revision 1 0 NEC Corporation ...

Page 2: ... Optical Drive 21 6 Flash FDD 21 7 Internal RDX LTO Drives 22 7 1 RDX LTO Drive Selection 22 7 2 RDX LTO Configuration 22 8 PCI Card 23 8 1 Network Interface Controller 23 8 2 SAS Controller 24 8 3 Serial Port Adapter 24 9 Other Add in Components 25 9 1 Power Unit 25 9 2 Fan Kit 25 9 3 Trusted Platform Module Kit 25 10 Add on Components 26 10 1 Input Devices 26 10 2 Server Management License 26 10...

Page 3: ...ntroller VRAM Integrated in Server Management Controller 32MB Resolution Color 1600 x 1200 16 7M 2 Interfaces 1 VGA 15 pin mini D sub 1 rear 1 to 2 Serial 9 pin mini D sub RS232 C 1 to 2 rear 4 USB 3 0 2 front 2 rear plus 1 internal USB 3 0 2 USB 3 1 2 rear 2 1000BASE T LAN connector RJ 45 2 rear 1 1000BASE T LAN connector for Management RJ 45 1 rear Server Management Aspeed AST2500 System Fan Sta...

Page 4: ...2 Gb s Optional RAID SATA RAID 0 1 10 Standard 1 SATA SAS RAID 0 1 5 6 10 50 60 Optional Hot Plug Supported with hot plug drive bay Optical Disk Drive Optional 5 inch Media Bays 2 Disk Drive Bays Hot plug 2 5 inch drive configuration 8 Hot plug 3 5 inch drive configuration 4 Non hot plug 3 5 inch drive configuration 4 Expansion Slots Total 4 slots available 1 PCIe 3 0 x16 x16 connector 3 PCIe 3 0 ...

Page 5: ...ors 1 Cache 8 MB Cores and Threads 6C 12T Chipset Intel C246 Chipset Memory Type DDR4 2666 ECC Unbuffered DIMM Standard Capacity 0 GB Maximum Capacity 64 GB 4 x 16 GB Internal Storage Standard Capacity 0 GB Maximum Capacity 48 TB 4 x 12 TB Disk Controller SATA 6 Gb s Integrated SATA SAS 6 12 Gb s Optional RAID SATA RAID 0 1 10 Standard 1 SATA SAS RAID 0 1 5 6 10 50 60 Optional Hot Plug Supported w...

Page 6: ... 5 to 48 C 41 to 118 F Optional 10 to 85 Non Operating 10 to 55 C 14 to 131 F 10 to 85 Regulatory and Safety FCC c UL CE CB RoHS BSMI CCC Operating Systems and Virtualization Software Microsoft Windows Server 2016 Standard Microsoft Windows Server 2016 Datacenter Red Hat Enterprise Linux 7 5 or later4 1 Embedded SATA RAID controller is supported only on limited OS 2 Maximum resolution available vi...

Page 7: ...lug 3 5 inch Drive Configuration Legend A Power Button J USB 3 0 Connectors B Dump NMI Button K Drive Bay Cover C BMC Reset Button L Cover Key D Power LED M Stabilizer E Power Capping LED N 5 25 inch Media Bay 1 F System Status LED 1 O 5 25 inch Media Bay 2 G System Status LED 2 P Optical Disk Drive H Global LED 1 Q 2 5 inch Drive Bay I Global LED 2 R 3 5 inch Drive Bay A G E C K J L I B D F H M P...

Page 8: ...0 December 2018 8 Rear Views Hot Plug Power Supply Configuration Non hot Plug Power Supply Configuration Legend A Serial Port Connector E Data LAN Connectors B VGA Connector F PCI Slots C USB Connectors G AC Inlet D Management LAN Connector H Power Supply Unit D C B A G E F H ...

Page 9: ...CONFIGRATION GUIDE NEC Express5800 T110j NEC Corporation Revision 1 0 December 2018 9 Dimensions mm Standard Bezel Non redundant Power Configuration Redundant Power Configuration 469 3 175 0 249 0 498 4 367 0 ...

Page 10: ... GUIDE NEC Express5800 T110j NEC Corporation Revision 1 0 December 2018 10 Dust Proof Bezel Non redundant Power Configuration Redundant Power Configuration 518 2 492 0 367 0 175 0 249 0 492 0 175 0 249 0 506 7 492 0 367 0 ...

Page 11: ...iagram Legend Standard components Mandatory components Expansion Slots Legend 1 PCIe 3 0 x4 x8 connector Full Height up to 173mm length 2 PCIe 3 0 x4 x8 connector Full Height up to 173mm length 3 PCIe 3 0 x16 x16 connector Full Height up to 312mm length 4 PCIe 3 0 x4 x8 connector Full Height up to 173mm length ...

Page 12: ... 4T 4 MB N8101 1465F Xeon E 2124 Processor Kit Intel Xeon Processor E 2124 3 3 GHz 4C 4T 8 MB N8101 1467F Xeon E 2124G Processor Kit Intel Xeon Processor E 2124G 3 4 GHz 4C 4T 8 MB N8101 1468F Xeon E 2126G Processor Kit Intel Xeon Processor E 2126G 3 3 GHz 6C 6T 12 MB N8101 1469F Xeon E 2134 Processor Kit Intel Xeon Processor E 2134 3 5 GHz 4C 8T 8 MB N8101 1470F Xeon E 2146G Processor Kit Intel X...

Page 13: ... size that you can actually use on your system Operating Systems Maximum Memory Size Supported by Operating Systems Maximum Available Memory Microsoft Windows Server 2016 Standard 1 Microsoft Windows Server 2016 Datacenter 1 24TB 64GB Red Hat Enterprise Linux 7 12TB 64 GB 1 The maximum available memory size of Hyper V systems is below Windows Server 2016 24 TB ...

Page 14: ...x 3 5 inch Fixed SATA HDD 2 5 inch Drive The 8x 2 5 inch drive cage can mount eight 2 5 inch SAS SATA drives as standard One cables is attached in drive cage for connection to maximum of four SAS SATA drives For five or more drives connection the additional cable is required Hot plug 3 5 inch Drive The Hot Plug 4x 3 5 inch drive cage can mount two 3 5 inch SATA drives as standard One cables is att...

Page 15: ...d 2 5 inch Drive Cage 8 x 2 5 inch hot plug drive bays 1x Mini SAS HD cable included N8154 80F NOTE Up to two kinds of drives selected from SAS 10K HDDs SAS 10K HDDs 512e SAS 15K HDDs SATA HDDs SAS SSDs SATA SSDs ME and SATA SSDs VE can be mixed in a system For five or more drives connection the additional cable is required 4 1 2 Hot plug 3 5 inch Drive Category Product Name Description Part Numbe...

Page 16: ...n installing M 2 SATA SSD only Embedded SATA controller or N8103 205 206 210 is supported with Wondows Mixed installation of M 2 SATA SSD and SSD HDD is supported on Embedded SATA controller 4 3 RAID Configuration 4 3 1 Embedded SATA Non RAID Controller Category Product Name Description Part Number Storage Controller Embedded SATA Controller 4 x 6Gb s SATA Standard NOTE Embedded SATA RAID controll...

Page 17: ...stallation Kit N8103 211 Flash Backup Recommended Flash Buckup Unit for LSI MegaRAID SAS 946N 8i 550mm Cable for Flash Backup Unit included NOTE It can not be connected to N8103 205 210 211 RAID Controller N8103 209 Cable RAID LED Cable LED cable for RAID controller NOTE It is required when N8154 81F 3 5 inch drive cage non hot plug or N8118 307 M 2 SATA SSD Installation kit is installed K410 444 ...

Page 18: ...150 482 1 2TB 10K Hot Plug 2 5 inch SAS HDD 1 x 1 2TB SAS HDD 2 5 inch 12Gb s 10 000 rpm 512n sector N8150 483 300GB 15K Hot Plug 2 5 inch SAS HDD 1 x 300 GB SAS HDD 2 5 inch 12Gb s 15 000 rpm 512n sector N8150 485 450GB 15K Hot Plug 2 5 inch SAS HDD 1 x 450 GB SAS HDD 2 5 inch 12Gb s 15 000 rpm 512n sector N8150 486 600GB 15K Hot Plug 2 5 inch SAS HDD 1 x 600 GB SAS HDD 2 5 inch 12Gb s 15 000 rpm...

Page 19: ...Hot Plug 3 5 inch SATA HDD 1 x 3 TB SATA HDD 3 5 inch 6Gb s 7 200 rpm 512n sector N8150 516 4TB 7 2K Non Hot Plug 3 5 inch SATA HDD 1 x 4 TB SATA HDD 3 5 inch 6Gb s 7 200 rpm 512n sector N8150 517 SATA HDD 512e 6TB 7 2K Non Hot Plug 3 5 inch SATA HDD 1 x 6 TB SATA HDD 3 5 inch 6Gb s 7 200 rpm 512e sector 8TB 7 2K Non Hot Plug 3 5 inch SATA HDD 1 x8 TB SATA HDD 3 5 inch 6Gb s 7 200 rpm 512e Sector ...

Page 20: ...SYSTEM CONFIGRATION GUIDE NEC Express5800 T110j NEC Corporation Revision 1 0 December 2018 20 Up to two M 2 SSDs can be mounted on M 2 installation kit two M 2 SSDs are required the same capacity ...

Page 21: ...DVD Dual drive DVD Dual drive Bus powered 1 5A required not including writing software N8160 101F NOTE Up to 1 optical drive can be connected When internal optical drive is installed ambient temperature is up to 40 C N8181 146F High temperature resistant Kit is not supported 6 Flash FDD Choose the Flash FDD if you need to prepare an alternative device for a floppy drive Product Name Description Pa...

Page 22: ...er Required SAS Controller LSI SAS9300 8i Host Bus Adapter 12Gbps SAS Int 8 SFF 8643 PCIe 3 0 x8 N8103 199 Cable Required Internal SAS Cable 1x SFF 8643 to 1x SFF 8482 SAS K410 449 00 Drive 1 drive available Internal LTO SAS LTO6 Half height Native capacity 2 5 TB Note When N8151 129 Internal LTO LTO6 is installed ambient temperature is 10 40 N8151 129 Internal LTO SAS LTO7 Half height Native capa...

Page 23: ... 10G SR 1 x SFP Module N8104 129 NOTE The system includes 2x 1000BASE T LAN ports by default NIC Teaming feature NIC Teaming and bonding features The Express5800 server supports NIC teaming which is the ability to configure multiple NICs to virtual single network interface for dual path and load balancing to fault tolerance and load balancing Network Load Balanding See the table below for supporte...

Page 24: ...r SAS Controller LSI SAS9300 8i Host Bus Adapter 12Gb s SAS Int 8 SFF 8643 x2 PCIe 3 0 x8 NOTE Up to one card can be installed For internal LTO connection N8103 199 SAS Controller LSI SAS9300 8e Host Bus Adapter 12Gb s SAS Ext 8 SFF 8644 x2 PCIe 3 0 x8 NOTE Up to one card can be installed For external LTO connection N8103 184 NOTE Please refer to the device s System Configuration Guide for support...

Page 25: ... 146F High temperature resistant Kit or N8146 71 Dust Proof Bezel is installed in a non redundant power supply model N8181 178 9 3 Trusted Platform Module Kit Product Name Description Part Number High temperature resistant Kit Required for high temperature operation over 40 up to 48 N8181 146F Note To apply this option there are some configuration limitation below Required System Configuration For...

Page 26: ... the remote terminals PC server as if accessing the local drives N8115 32 NOTE Remote KVM and remote media features are not available for virtual machines 10 3 Dust Proof Kit The server supports the dust resistant feature Choose the following kit to install the system in dusty places Category Product Name Description Part Number Front Bezel Dust Proof Bezel Including 1 set of filter replacement se...

Page 27: ... Command Line Protocol DMTF compliant Remote control via Web browser multi user login at the same time Remote batch No UPS required ESMPRO SM required 6 6 Others Set automatic IP address via DNS DHCP LDAP Active Directory verification user control Clock synchronization of main unit and the RTC 5 5 Access log collection IPv6 Remote control via Web browser DMTF compliant CLP only Industry Standard I...

Page 28: ...lots Slots Part Number Product Name 1 2 3 4 N8103 205 RAID Controller 2GB RAID 0 1 5 6 1 N8103 206 RAID Controller 2GB RAID 0 1 WT WB 1 N8103 207 RAID Controller 2GB RAID 0 1 5 6 WT WB 1 N8103 208 RAID Controller 4GB RAID 0 1 5 6 1 N8103 210 RAID Controller 2GB RAID 0 1 WT 1 N8103 211 RAID Controller 2GB RAID 0 1 5 6 WT 1 N8104 157 Dual Port 10GBASE T Adapter 3 4 1 2 N8104 149 10GBASE SFP Adapter ...

Page 29: ...pter SFP 2ch Up to one card from the following can be installed and no limitations for N8118 307 Dual M 2 SATA Mount Kit N8117 01A Serial Port Adapter N8103 184 SAS Controller N8103 199 SAS Controller N8104 150 1000BASE T Adapter N8104 151 Dual Port 1000BASE T Adapter N8104 157 Dual Port 10GBASE T Adapter No Cannot install N8104 149 10GBASE SFP Adapter SFP 2ch Up to one card from the following can...

Page 30: ...s disabled Keep the setting disabled to use other operating systems and or software Supported OS and Software for Secure Boot Mode Operating System Supported Boot Mode Secure Boot Mode Windows Server 2016 UEFI Software Related to Boot Supported Boot Mode Secure Boot Mode System Diagnostics Utility UEFI EXPRESSBUILDER UEFI Supported Boot Device for Secure Boot Mode Supported Boot Device Part Number...

Page 31: ...trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries Linux is a trademark of Linus Torvalds Red Hat is a registered trademark of Red Hat Inc in the U S All other products brands or trade names used in this document are trademarks or registered trademarks of their respective holders NEC shall not be liable for technical or editorial errors or om...

Page 32: ...SYSTEM CONFIGRATION GUIDE NEC Express5800 T110j NEC Corporation Revision 1 0 December 2018 32 Revision History Revision Date Description 1 0 December 28 2018 Initial release ...

Reviews: