1. Installing Internal Optional Devices
Express5800/T110i-S User’s Guide
81
Chapter 2 Preparations
Firmware(SDR) Updating
1.13.4
Apply SDR Firmware after the installation of internal simple UPS Control Kit.
SDR Update Tool CD-ROM is attached parts of the server.
To apply SDR Firmware, follow the procedure below.
1.
Connect a power code to the server.
2.
Wait for 40 seconds after AC power is supplied to the server.
3.
Turn on the server.
4.
Insert an “SDR Update Tool” CD-ROM to the optical disk drive and update SDR Firmware.
Precautions for operating with internal battery
1.13.5
•
Charge the battery before you start operation. You can check charging state and settings of internal battery
with EXPRESSSCOPE Engine 3 or NEC ESMPRO. For details, see the manual provided with each tool.
•
Following is the limitations when using internal battery.
Up to 4 hard disk drives can be installed.
High Temperature Resistant Kit cannot be mounted.
The backup device cannot be mounted on 3.5-inch additional bay (2).
Redundant power unit cannot be installed.
•
If errors are detected after you finished installation, confirm the mount procedure and confirm the cable of
internal battery is surely connected.
•
The setting to start shutdown when power supply abnormality occurs is enabled by default.