![background image](http://html1.mh-extra.com/html/nec/express5800-r120g-2m/express5800-r120g-2m_user-manual_3944086141.webp)
2. BIOS Setup Utility (SETUP)
Express5800/R120g-2M User’s Guide
141
Chapter 3 Setup
2.4
Cases that Require Configuration
Only if a case applies to any of following cases, use SETUP to change a parameter which was configured as
factory setting. Other than cases described below, do not change the settings. A list of SETUP parameters
and factory settings are described in
Chapter 2 (1. System BIOS)
in "
Maintenance Guide
".
Category
Description
To be changed
Remark
Basic
Change date and time
Main
System Date
Main
System Time
Configurable on OS
On/Off NumLock on power ON
Boot
Bootup Numlock State
ON
or
OFF
On/Off the function to display
NEC logo during POST
Boot
Quite Boot
Disabled
By pressing <Esc> key, prevent
the display of the logo.
Memory
Add or change DIMM
Advanced
Memory Configuration
Memory Retest
Yes
After rebooting,
Memory Retest
changes
No
automatically.
Use memory RAS feature
Advanced
Memory Configuration
Memory RAS Mode
change to RAS
mode
Some of RAS features may not
be used depending on DIMM
configuration.
Optional
board
Start the system from installed
option board.
Advanced
PCI Configuration
PCI
Device Controller and Option ROM
Settings
PCIXX Slot Option ROM
Enabled
XX
is PCI slot number of the
installed option board
Boot
Set the boot mode to UEFI
mode according to your OS.
Boot
Boot Mode
UEFI
*1
Select UEFI mode for the following OS.
– Windows Server 2012
– Windows Server 2012 R2
See "
Before Starting Setup
" in
Chapter 1 (Installing Windows)
in
Installation Guide
to
determine the boot mode.
Set the boot mode to Legacy
BIOS mode according to your
OS.
Boot
Boot Mode
Legacy
*1
Select Legacy mode for the following OS.
– Windows Server 2008R2
-
VMware ESXi 5
-
VMware ESXi 6
See "
Before Starting Setup
" in
Chapter 1 (Installing Windows)
in
Installation Guide
to
determine the boot mode.
Change the boot order of
devices
Boot
Boot Option Priorities
Change the boot priority
When you use
EXPRESSBUILDER, set
CD/DVD
to the highest priority.
Use remote power on feature
(via RTC alarm)
Advanced
Advanced Chipset
Configuration
Wake On RTC Alarm
Enabled
Use console redirection feature
Advanced
Serial Port Configuration
Console Redirection Settings
Change respective setting.
In console redirection
connection, if the corrupted text
is displayed on terminal screen,
change font type (character
code) appropriate to your
environment.
Enable X2APIC feature
according to your OS.
Advanced
Processor Configuration
X2APIC
Enabled
*1
Enable X2APIC for the following OS.
– Windows Server 2012
– Windows Server 2012 R2
See "
Before Starting Setup
" in
Chapter 1 (Installing Windows)
in
Installation Guide
to select
Enabled
or
Disabled
.
Disable X2APIC feature
according to your OS.
Advanced
Processor Configuration
X2APIC
Disabled
*1
Disable X2APIC for the following OS.
– Windows Server 2008R2
-
VMware ESXi 5
-
VMware ESXi 6
See "
Before Starting Setup
" in
Chapter 1 (Installing Windows)
in
Installation Guide
to select
Enabled
or
Disabled
.