![NEC Express5800/GT110d-S (2C/i3-2120) EXP281A User Manual Download Page 132](http://html1.mh-extra.com/html/nec/express5800-gt110d-s-2c-i3-2120-exp281a/express5800-gt110d-s-2c-i3-2120-exp281a_user-manual_3929646132.webp)
2. System BIOS Setup
Express5800/GT110d-S User’s Guide
132
Chapter 3 Setup
2.4
Cases that Require Configuration
Only if a case applies to any of following cases, use the SETUP utility to change a parameter which was
configured as factory setting. Other than cases described below, do not change the settings. A list of SETUP
parameters and factory settings are described in
Chapter 2 (1. Details of System BIOS)
in "
Maintenance
Guide
".
Category
Description
To be changed
Remark
Change date and time
Main
→
System Date
Main
→
System Time
Configurable on OS
On/Off NumLock on power ON
Boot
→
Bootup Numlock State
Basic
On/Off the function to display
the NEC logo during POST
Boot
→
Quite Boot
→
Disabled
By pressing the <Esc> key,
prevent the display of the logo.
Optional
board
Install RAID Controller board
Advanced
→
PCI Configuration
→
PCI
Slot n Option ROM
→
Enabled
n
is PCI slot number of the
RAID Controller
Change the boot order of
devices
Boot
→
Boot Option Priorities
→
Change the boot priority
Use remote power on function
(from modem)
Advanced
→
Advanced Chipset
Configuration
→
Wake On Ring
→
Enabled
Use remote power on function
(from RTC alarm)
Advanced
→
Advanced Chipset
Configuration
→
Wake On RTC Alarm
→
Enabled
Boot
Control from HW console
terminal
Advanced
→
Serial Port Configuration
→
Change respective setting.
Security
Set a password
Security
→
Administrator Password
→
Enter a password
(Set a password for Administrator first
and then User)
There are two types of
password; Administrator and
User.
Settings for User password is
limited compared to for
Administrator.
When the server is supplied
with power from UPS, always
turn on the power.
Server
→
AC-LINK
→
Power On
If it is turned off by using
POWER switch, leave it OFF
even when UPS supplies
power.
Server
→
AC-LINK
→
Last State
UPS
Powerlink
Keep the power OFF even
when UPS supplies power.
Server
→
AC-LINK
→
Remains off