Updating BMC Firmware
3-6
Express5800/
ftServer
: System Administrator’s Guide for the Linux Operating System
4.
Obtain the
latest BMC image
for the Express5800/ftServer
and cop
y
it to the ftServer tmp folder.
N O T E
All ftServers running a supported Linux distribution and
Express5800/
ftServer
system software for the Linux
Operating System (
Express Builder
) use the same BMC firmware.
5. Type the following commands to update the BMC firmware on each I/O element:
#
/opt/ft/bin/ftsmaint burnProm
path and filename for the BMC firmware
Updated firmware on the device at path 10/120.
#
/opt/ft/bin/ftsmaint burnPROM
path and filename for the BMC firmware
Updated firmware on the device at path 11/120.
6. Type the following commands to verify that your BMC firmware is duplexed (be
sure that the opstate is
DUPLEX
):
#
/opt/ft/bin/ftsmaint ls 10/120
#
/opt/ft/bin/ftsmaint ls 11/120
7. Type the following commands to verify that the I/O elements are duplexed (be sure
that the opstate is
DUPLEX
):
#
/opt/ft/bin/ftsmaint ls 10
#
/opt/ft/bin/ftsmaint ls 11