![background image](http://html1.mh-extra.com/html/nec/express5800-320ma/express5800-320ma_planning-manual_3899134062.webp)
Rack-Mountable System Specifications
A-12
Express5800/320Ma: Site Planning Guide
Features
Processors
Express5800/320Ma 3.2 GHz
: One or two Intel
Xeon
3.2 GHz
processors with Hyper-Threading Technology
in each CPU- I
⁄
O enclosure
Express5800/320Ma 3.6 GHz
: Two Intel
Xeon 3.6
GHz
processors with Hyper-Threading Technology in
each CPU- I
⁄
O enclosure
Express5800/320Ma Dual-Core
: Two Dual-Core
Intel Xeon 2.8 GHz processors with Hyper-Threading
Technology in each CPU- I
⁄
O enclosure
Memory
Eight physical dual data rate (DDR) inline memory
module (DIMM) slots in each CPU- I
⁄
O enclosure
Ports
Two 10/100/1000-Mbps Ethernet ports in each
CPU- I
⁄
O enclosure
Two AC power connectors, one VGA port, two serial
ports, and three USB ports
PCI slots
Express5800/320Ma 3.2 GHz
systems: One
user-configurable, low-profile PCI adapter slot operating
at 64-bits and 100 MHz in each CPU- I
⁄
O enclosure
(you can add two full-height PCI adapter slots in each
CPU-I/O enclosure with the optional AK533 riser
assembly kit)
Express5800/320Ma 3.6 GHz and Dual-Core
systems: One low-profile PCI adapter slot and two
full-height PCI adapter slots operating at 64-bits and
100 MHz, all user-configurable, in each
CPU- I
⁄
O enclosure
VTM
A Virtual Technician Module (VTM), a system
management module CPU- I
⁄
O enclosure
When VTMs are installed, a 10/100-Mbps Ethernet
ports dedicated to the VTM is present for each VTM.
Disk Drives
Three Serial ATA (SATA) disk drives in each
CPU- I
⁄
O enclosure
Table A-3. Rack-Mountable System Specifications (Continued)
Summary of Contents for Express5800/320Ma
Page 1: ...NEC Solutions America Inc NR573 Express5800 320Ma Site Planning Guide...
Page 10: ...Preface x Express5800 320Ma Site Planning Guide...
Page 18: ...System Documentation 1 8 Express5800 320Ma Site Planning Guide...
Page 40: ...Connecting a System Directly to a UPS 5 6 Express5800 320Ma Site Planning Guide...
Page 50: ...Sample PDU Usage Calculation 7 6 Express5800 320Ma Site Planning Guide...
Page 77: ...Standards Compliance Standards Compliance C 3 VCCI Note BSMI Note...
Page 78: ...Standards Compliance C 4 Express5800 320Ma Site Planning Guide...