1. POST Error Message
Express5800/T110f-S, R110f-1E, T110f-E Maintenance Guide
134
Chapter 3 Appendix
(1) Error
messages
(1/4)
Error Message
Description
Action
8000
System variable is
corrupted.
BIOS settings are invalid.
Run the setup utility, and then
execute
Load Setup Defaults
and
specify the necessary settings. If the
same error continues to occur,
contact your sales representative.
8002
Check date and time
settings
The real-time clock is incorrect.
Run the setup utility, and then specify
the correct date and time. If the same
error continues to occur, contact your
sales representative.
8006
System configuration data
cleared by Jumper.
The setup utility settings were
cleared by the jumper.
8007
SETUP Menu Password
cleared by Jumper.
The setup utility password was
cleared by the jumper.
See
Chapter 1 (7. Resetting and
Clearing the Server).
8020
BIOS update error.
BIOS update failed.
Try BIOS update again. If it fails
again, contact your sales
representative.
8021
Recovery jumper is set,
but recovery images is not
found.
The recovery jumper is set but
the BIOS recovery failed.
8800 DXE_NB_ERROR
An error was detected during
initialization of the chipset
8801 DXE_NO_CON_IN
8802 DXE_NO_CON_OUT
An error was detected during
initialization of the console.
9000
Unsupported CPU
detected
An unsupported CPU was
detected.
9E80
Forced to use CPU with
error.
A CPU error occurred.
Contact your sales representative.
AB00
Memory not detected
No valid memory is installed.
Check if the memory modules are
properly installed. If the same error is
displayed consecutively, contact your
sales representative.
AE01
DIMM1 has been disabled.
A memory error occurred.
DIMM1 has been disabled.
AE02
DIMM2 has been disabled.
A memory error occurred.
DIMM2 has been disabled.
AE03
DIMM3 has been disabled.
A memory error occurred.
DIMM3 has been disabled.
AE04
DIMM4 has been disabled.
A memory error occurred.
DIMM4 has been disabled.
AE81
DIMM1 with error is
enabled.
An error in DIMM1 occurred.
The DIMM1 was forcibly enables
because all memory is currently
disabled.
AE82
DIMM2 with error is
enabled.
An error in DIMM2 occurred.
The DIMM2 was forcibly enables
because all memory is currently
disabled.
Contact your sales representative.
B000
Expansion ROM not
initialized
There is no memory for
expanding option ROM.
B001
Expansion ROM not
initialized - PCI Slot 1
(Express5800/T110f-S,
T110f-E)
Option ROM expansion in PCI
slot 1 failed.
B002
Expansion ROM not
initialized - PCI Slot 2
(Express5800/T110f-S,
T110f-E)
Option ROM expansion in PCI
slot 2 failed.
B003
Expansion ROM not
initialized - PCI Slot 3
(Express5800/T110f-S,
T110f-E)
Option ROM expansion in PCI
slot 3 failed.
If the PCI board does not connect to a
bootable device, disable the Option
ROM Scan for that board.