“Confidential, Do Not Duplicate without written authorization from NEC.”
4-
8
TROUBLESHOOTING
Lamp Over Temp.
Over Temp. Out
Over Temp.In
Over Temp. Chest
Over Temp. DMD
Over Temp. Rear
No
Yes
Is the ambient temperature 35
°
C or above?
Adjust air conditioning so that the
ambient temperature is below 35
°
C
or equipment operating temperature
(upper limit).
Yes
No
Is there no clogging at the exhaust port?
Remove the clogging obstacle.
Yes
No
Is there no clogging in the air filter?
Replace the air filter.
Yes
No
Is ventilation normal when the power is ON?
Is the potential at #1 on the PJDIV PWB side
of Cable TH maintained at the GND level?
Is it impossible to eliminate malfunction even
after the replacement of the PJDIV PWB?
Check the connectors in the CPU PWB and
between the CPU PWB and the PJDIV PWB.
Replace them, as required.
Replace the related fan if there is any
error such as fan stop.
Yes
No
Check connections in regard to dis-
connections, if any, in Cable TH and
examine the condition of thermostat
(short-circuited at room temperature).
Yes
No
End of repair
Summary of Contents for DLP CINEMA NC1600C
Page 7: ...NC1600C User s Manual DLP Cinema Projector ...
Page 53: ...47 6 Appendix 6 5 Outline Drawing 700 503 360 990 Units mm ...
Page 63: ... NEC Display Solutions Ltd 2007 Ver 2 07 07 ...
Page 64: ...NC TP6402 NC TP6401 User s Manual Touch Panel Controller NEC Viewtechnology Ltd ...
Page 71: ...G 3 MEMO Important Information ...
Page 94: ... NEC Viewtechnology Ltd 2005 2006 Printed in Japan Ver 2 06 06 ...
Page 95: ...7N8P6692 Printed on recycled paper NC TP6402 NC TP6401 User s Manual ...
Page 382: ...01154041 NC1600C ...