4-35
5. Adjustment Mode Setting
AUTO LEVEL
1) Enter an input signal of VESA (1280
×
1024 @75Hz) input signal all white.
2) Enter the factory mode according to “4.2 Factory and Service mode”
3) Pressing the (-) or (+) button, adjust the high light to [AUTO LEVEL]. When the SELECT button is pressed,
adjustment of the bias and the gain is carried out.
4) When adjustments have been finished, Pressing the (-) or (+) button, adjust the high light to [EXIT].
When the SELECT button is pressed, close the factory mode.
Note:
Check whether RGB data is as follows in the case of Auto Color adjustment.
Auto Color R/G/B Data for QDI panel (QDI QD17EL07)
R G B
9300 69 75 65
7500 78 76 53
6500 85 82 53
1) Select “R”, “G”, or “B” in the factory mode by pressing the “- (LEFT)” or “+ (RIGHT)” button.
2) When the MENU button is pressed, the high light moves to R/G/B data.
3) Press the “- (LEFT)” or “+ (RIGHT)” button to turn a numerical value is changed.
4) After the MENU button has been pressed, select “AUTO” and press the MENU button again.
This causes the factory mode to be closed. (Try to display the OSD to confirm whether the service mode or
the factory mode has been closed.)