5-6
2.6 Check Power Manage Function
Monitor should enter to power saving mode if the following condition occurs.
Mode Horizontal Vertical
Power
Supply
Input Timing
Power Consumption
On
ON
ON
240Vac
VESA 1024X768 (75Hz)
34W
Stand-by
OFF
ON
240Vac
VESA 1024X768 (75Hz)
2W
Suspend
ON
OFF
240Vac
VESA 1024X768 (75Hz)
2W
Off
OFF
OFF
240Vac
VESA 1024X768 (75Hz)
2W
3. External Inspection on the LCD Module
3.1 For QDI Panel (QDI 17EL0707 Rev.02)
External Inspection
Inspection item
Criteria
Reject count (N)
D > 0.5mm
N = 0
0.5mm
≥
D
≥
0.15mm
N
≤
3
D < 0.15mm
Don’t care
Black spot, White spot,
Foreign circular
Material Dent &bubble
Minimum distance between defects: 10mm
L > 4.0mm; W > 0.1mm
N
≤
0
4mm
≥
L
≥
2.0mm, 0.1mm
≥
W
≥
0.01mm
N
≤
3
Scratches, lint
L: length; W: width (mm)
L < 2.0mm, W< 0.01mm
Don’t care
The external visual inspection: The inspection shall be conducted by using a single 20W fluorescent lamp for
illumination and the distance between the MODULE and the eyes of the inspector shall be 35 cm or more.
* The area for external inspection is active area plus 1.0mm width. (Upper, Lower, Left and Right)
L
W
L = Longest
Length: L
Average Diameter: D
D= a + b
2
a
b