8-10
Issue 2 December 1995
Switch Integration Device Administration
6. To change the default value shown, press the left or right arrow key to
toggle through the optional values. The value you set for the baud rate
must equal the value set for the SID to the INTUITY System communication
link baud rate. Do not set two different values for these links. Stop
pressing the arrow keys when you find the value you want to use.
NOTE:
In Chapter 3 you completed worksheet A which contained lines for
the MCI baud rate and the SMDI baud rate. Refer to the worksheet
to review the baud rates you selected. For the INTUITY system, the
baud must be set to 2400.
7. After you select a baud rate, press
to confirm your choice and move to
the next form.
After you press enter, you see the PARITY form as shown in the following
example:
8. To change the default parity value shown in the field, press the left or right
arrow key to toggle through the optional values. Stop pressing the arrow
keys when you find the parity value you want to use.
9. After you select a parity, press
to confirm your choice and move to the
next form.
After you press enter, you see the BYTE LENGTH form as shown in the
following example:
10. To change the default byte length shown in the field, press the left or right
arrow key to toggle through the optional values. Stop pressing the arrow
keys when you find the byte length you want to use.
11. After you select a byte length, press
to
confirm
your choice and move
to the last form.
After you press the key, you see the STOP BITS form as shown in the
following example:
MCI
Parity:
EVEN
<- ->1
MCI
Byte Length:
7 Bits
<- ->1
MCI
Stop Bits:
1
<- ->1
Summary of Contents for 2400
Page 2: ...Blank Page...
Page 8: ...Contents viii Issue 2 December 1995...
Page 36: ...2 10 Issue 2 December 1995 Switch Integration Device Basics...
Page 42: ...3 6 Issue 2 December 1995 Switch Integration Planning...
Page 52: ...4 10 Issue 2 December 1995 Hardware Installation...
Page 70: ...6 10 Issue 2 December 1995 Administering the INTUITY System for the NEAX Integration...
Page 104: ...8 16 Issue 2 December 1995 Switch Integration Device Administration...
Page 122: ...A 10 Issue 2 December 1995...
Page 128: ...B 6 Issue 2 December 1995...