NDUSTRIA™ Infrared Electric Manual
10
SECTION 5: GENERAL SPECIFICATIONS
5.2 Heater Specifi cations
These heaters are designed and manufactured for commercial heating applications for indoor and outdoor use.
May also be used for outdoor residential use.
Certifi cation -Standard for Fixed and Location-Dedicated Electric Room Heaters, UL 2021, and the Canadian
Standard for Electric Air Heaters, CSA C22.2 No. 46.
IP65 rated - This product is water resistant and protected against multi-directional, low-pressure water jets.
Cut/Pinch Hazard
Wear protective gear
during installation,
operation and service.
WARNING
Failure to follow these instructions can result in death, electric shock, injury or property damage.
Burn Hazard
Keep all persons,
especially children,
away from heater.
Do not touch any part
of the heater.
Heater is very hot.
Fire Hazard
Keep all flammable
objects, liquids and
vapors the minimum
required clearances to
combustibles away
from heater.
Some objects will
catch fire or explode
when placed close to
heater.
DANGER
Electrical Shock Hazard
Disconnect electric
before service.
Heater must be
connected to a properly
grounded electrical
source.
Model
Color
Volts
Watts
Amps
Phase
Cord
Quantity
Lamp
Quantity
Cord
Length
(ft/m)
NEL-15B Black
120
1500
12.5
1
1
1
6/1.8
NEL-15G Gray
120
1500
12.5
1
1
1
6/1.8
NEL-15B-RM Black
120
1500
12.5
1
1
1
6/1.8
NEL-15G-RM Gray
120
1500
12.5
1
1
1
6/1.8
NEL-30B Black 208/240
2250/3000
10.8/12.5
1
2
2
6/1.8
NEL-30G Gray
208/240
2250/3000
10.8/12.5
1
2
2
6/1.8
NEL-60B Black 208/240
4500/6000
21.8/25.0
1
3
3
6/1.8
NEL-60G
Gray
208/240
4500/6000
21.8/25.0
1
3
3
6/1.8