NDUSTRIA™ Infrared Electric Manual
7
3.3.1 Remote Control - Model NEL-15(B/G)-RM
Only
Heater is equipped with mechanical switch that con-
trols on, off and remote standby mode for use with
optional remote control.
0 Power Off position
I When switch is in I position, heater will turn on and
remote control is not operational. To turn heater off,
push switch to 0 position. ON/OFF functionality with I
and 0 positions do not require remote control.
II When Switch is in II position, heater in STANDBY
mode and functionality will be controlled by remote
control.
3.3.2 Remote Control Functionality (optional)
Requires 2 AAA 1.5V batteries (not included)
To turn heater on, press ON on remote.
To turn heater off, press OFF on remote.
3.4 Electrical Installation for Models NEL-30(B/G)
and NEL-60(B/G)
Use a ground fault protection device.
1. Supply voltage must correspond to the voltage indi-
cated on the unit’s rating plate.
2. The cord from each terminal box must be hard
wired and properly grounded.
3. Multiple switches and circuits may be required to
accommodate the Amp load of the heater. Multiple
separate power cords are provided which allows fl exi-
bility in control.
DANGER
Electrical Shock Hazard
Disconnect electrical supplies before
performing service or maintenance.
Installation must be done by a certified
electrician and must adhere to local, state
and national electrical codes.
Control must be properly grounded to an
electrical source.
Failure to follow these instructions can
result in death, electrical shock or property
damage.