10. EXTRA SELECTIONS
Dip switches 5,6,7,8 are dedicated to some extra
selections for the
POWER
SERVICE
PSB
setup.
Dip Switch 5: silent mode
Useful if you don’t want to be disturbed by the
POWER
SERVICE
PSB
's cooling fan or alarm and you
have low power consumption. By activating this mode,
the maximum charging current may be reduced by the
POWER
SERVICE
PSB
to safeguard its integrity.
Silent mode can be activated from the dip switch on
the
POWER
SERVICE
PSB
, or via the display and/or
mobile app if a Bluetooth N-BUS device is present in
the N-BUS network (such as Tempra Lithium Battery)
Dip Switch 6: input current limit
This setting limits the input current to the
POWER
SERVICE
PSB
by 50% please see the table
below for more details. It can be useful when the power
source (e.g.: Alternator) is not so powerful, this setting
can be activated in order not to stress the system. This
function can only be activated by the Dip Switch 6, can
not be activated by the Controller (DTB01 or App).
17
Silent mode ON
Silent mode OFF
Current limit ON
Current limit OFF