9. CHARGING CURVE SETUP
The
POWER
SERVICE
PSB
supports the charging of
lithium iron phosphate (LiFePO
4
), lead/acid (AGM, Gel,
Wet) leisure batteries with appropriate charging curves.
Use the Dip-Switches (Fig.3 - Ref. G), numbers 2, 3, 4, to
select the desired charging curve.
15
D Curve: AGM /2
C Curve: AGM /1
12V
24V
Max voltage (Vabs.)
14,2V 28,4V
Float voltage (Vfloat)
13,5V 27,0V
Max desulfation voltage
OFF OFF
12V
24V
Max voltage (Vabs.)
14,4V 28,8V
Float voltage (Vfloat)
13,8V 27,6V
Max desulfation voltage
OFF OFF
12V
24V
Max voltage (Vabs.)
14,7V 29,4V
Float voltage (Vfloat)
13,6V 27,2V
Max desulfation voltage
OFF OFF
12V
24V
Max voltage (Vabs.)
14,7V 29,4V
Float voltage (Vfloat)
13,6V 27,2V
Max desulfation voltage 15,6V 31,2V
F Curve: LiFePO
4
/2
E Curve: LiFePO
4
/1
12V
24V
Max voltage (Vabs.)
14,5V 29,0V
Float voltage (Vfloat)
13,8V 27,6V
Max desulfation voltage
OFF OFF
12V
24V
Max voltage (Vabs.)
14,5V 29,0V
Float voltage (Vfloat)
OFF OFF
Max desulfation voltage
OFF OFF
A Curve: GEL
B Curve: Wet
Summary of Contents for POWERSERVICEPSB PSB 12-40