![NDS POWERSERVICEPSB PSB 12-40 User Manual Download Page 14](http://html.mh-extra.com/html/nds/powerservicepsb-psb-12-40/powerservicepsb-psb-12-40_user-manual_715025014.webp)
The
AUX
connection can be used for:
• RV control unit output (eg CBE, Sargent, Schaudt, Nord
Elettronica, etc…).
• Split-charge relay.
• Appliances such as the fridge, lights, pump, etc.
How it works:
•
Engine OFF and D+ (or i) not active
-
Appliances powered by the leisure batteries.
•
Engine ON and D+ (or i)
attivo
- Appliances
powered directly by the alternator.
8. ALTERNATOR TYPE SETUP
Please set the Dip Switch according to your vehicle
alternator type.
14
NOTE
If you choose the i signal instead of the D+ one, please
remember to start the engine as soon as possible.
STANDARD ALTERNATOR CONFIGURATION
Dip switch
setup
Activation
threshold
Deactivation
threshold
13,3 V
12,7 V
SMART ALTERNATOR CONFIGURATION
Dip switch
setup
Activation
threshold
Deactivation
threshold
11,7 V
11,25 V
Summary of Contents for POWERSERVICEPSB PSB 12-40
Page 35: ...35 ...