Power supply from solar panel
If the following situations occur:
•
I or D + signal not active,
•
solar panel illuminated by sunlight with AN OPEN-CIRCUIT
voltage higher than 16V,
the
power
service
starts charging using the integrated solar
regulator with PWM technology; charging phases are the same
as those provided by the alternator and by an external mains
supply
.
the device stops charging using the solar controller when the
panel voltage becomes lower than the service battery (there is
not enough light to sustain a charging current)
.
POWER SUPPLY FROM 230V MAINS CONNECTION (GOLD series
only)
If the i or D+ signal is not active, and the power supply is
connected and active, the
power
service
gold GIVES PRIORITY TO
THE MAINS POWER SUPPLY AND STOPS USING THE SOLAR PANEL.
the power source is selected by power priority, as below:
1.
Alternator.
2.
MAINS POWER SUPPLY (GOLD only).
3.
Solar Panel.
The charging source used will be displayed by the relevant LED.