30
Location to Location Receive Setup
Move the RS-232 cable to the
Receive
unit’s
RS-232 IN
connector (page 30). Launch the
ConfigOR-G2
program, described on the previous page. Select the COM port to be used, then click the
Connect
button.
Click the Connect button, a successful connection will ‘gray out’ the
Connect
button, fill in the
IP
Address, Subnet Mask and Gateway
windows. The message in the lower left corner will change to:
Connected
.
Note the
Receive
unit’s
IP Address.
Close the
ConfigOR-G2
program.
Move the RS-232 cable back to the
Transmit
unit’s
RS-232 IN
connector (page 30). Launch the
ConfigOR-G2
program, select the COM port to be used, then click the
Connect
button.
Type the
Receive
unit’s
IP address
into the
IP Address
window in the
Remote IP Address
frame.
Optionally, the
Transmit
unit’s
IP address
may be entered in the
Receive
unit’s
IP Address
window in
the
Remote IP Address
frame. Doing so allows streaming to be initiated or terminated from the
Transmit
or the
Receive
unit.
Click the
Apply
button . Close the
ConfigOR-G2
program. This completes the software setup.
Establishing a Streaming Connection
is described on the following pages.
Summary of Contents for ConductOR