NCR RealScan 7875-7000/8000 Installation Guide
AIP-00342 Release B
06/03
9 of 56
Service Clearance
Item Flow Area
20784
A = 20.3 cm (8 in.) minimum if checkstand structure is not removable for servicing.
2.5 cm (1 in.) minimum if checkstand structure is removable for servicing.
B = 35.6 cm (14 in.) minimum if checkstand structure is not removable for servicing.
17.8 cm (7 in.) minimum if checkstand structure is removable for servicing.
C = 18.1 cm (7 1/8 in.) minimum clearance to closest checkstand panel.
The NCR 7875-7000/8000 must not be supported by a bottom panel.
Note:
RealScan 7875-8000 units with a Produce Guard must have enough clearance to remove
the Produce Guard for cleaning. The dimensions given here satisfy these requirements.
Mounting surface for keyboard must be
removable for the following.
• Servicing the unit.
• Removing the 7875-8000 Produce Guard.
• Replacing the vertical window.
B
C
A
A
Item Diverter
Item Diverter
(Must be removable to service
Scanner/Scale in checkstand)
7.25 in. (18.4 cm)
14957
Note:
The Item Diverter is not used in most self-checkout installations.