11-2 Chapter 11: Diagnostic LEDs
•
Power
Status
LED
‐
This
White
LED
is
used
to
illuminate
the
NCR
Logo
on
the
bezel
to
indicate
that
the
system
is
on.
In
addition,
this
LED
blinks
when
the
system
is
in
S3
suspend
mode.
•
LAN
Link
‐
This
Green
LED
lights
to
indicate
that
the
system
is
attached
to
a
LAN.
It
stays
on
whenever
the
LAN
is
present,
even
if
the
unit
is
powered
off.
This
LED
also
flashes
to
indicate
LAN
activity.
•
HDD
Activity
–
This
Green
LED
lights
whenever
there
is
activity
to
the
hard
drives.
•
Diagnostic
LEDs
(A
‐
F)
–
These
six
Red
LEDs
are
used
to
indicate
various
failure
modes
of
the
system,
primarily
when
the
system
fails
to
boot.
These
LEDS
are
located
behind
the
Front
Base
Cover,
making
them
visible
only
when
they
are
lit.
•
Power
On
Self
Test
(POST)
Error
(A
‐
C):
These
three
LEDS
Flash
during
boot
‐
up.
If
boot
fails,
different
combinations
of
LEDs
indicate
the
point
where
POST
failed
to
aid
in
troubleshooting.
BIOS
Checkpoint
Description
A B C
Normal
Operating
condition
after
proper
boot
OFF
OFF
OFF
D1
Keyboard
Controller
BAT
test.
Check
if
waking
from
power
management
suspend
state.
Save
power
on
CPUID
value
in
scratch
CMOS.
OFF
OFF
ON
D4
Test
Base
512kb
memory.
Adjust
policies
and
cache
first
8MB.
Set
stack.
(Indicates
Bad
DIMM)
OFF
ON
OFF
04
Verify
CMOS
and
update
if
necessary.
Initialize
data
variables.
Also
indicates
that
SATA
device
is
not
initializing.
(Indicates
SATA
Failure)
OFF
ON
ON
0A
Initialize
keyboard
controller
ON
OFF
OFF
Indicates
that
there
is
no
memory
detected
in
system.
ON
ON
ON
•
Temperature
Warning
(D):
Lights
when
temperature
threshold
is
exceeded
and
CPU
is
throttling
to
prevent
overheating.
System
performance
may
be
affected
during
throttling.
•
CPU
Voltage
Bad
(E):
Lights
if
CPU
is
not
receiving
adequate
power
to
boot
the
system
(Check
power
supply
and
internal
connection).
•
Power
Supply
Bad
(F):
Lit
when
power
supply
is
not
providing
proper
voltage
to
internal
connections,
including
powered
serial
ports.
Isolates
failure
to
internal
power
supply.
A,
D,
E,
and
F
LEDs
illuminate
in
this
case.
Summary of Contents for RealPOS 70XRT
Page 1: ...NCR RealPOS 70XRT 7403 POS Workstation Release 1 2 User Guide B005 0000 1872 Issue E ...
Page 80: ...4 6 Chapter 4 Installing a Secondary Dual Display ...
Page 124: ...7 10 Chapter 7 Installing a RAID System ...
Page 129: ...Chapter 8 2x20 Customer Display Interface 8 5 CP437 ...
Page 130: ...8 6 Chapter 8 2x20 Customer Display Interface CP858 ...
Page 131: ...Chapter 8 2x20 Customer Display Interface 8 7 CP866 ...
Page 132: ...8 8 Chapter 8 2x20 Customer Display Interface CP932 ...
Page 134: ...9 2 Chapter 9 Cash Drawer Interface ...
Page 142: ...10 8 Chapter 10 Wedge to USB MSR Software Migration ...
Page 146: ...11 4 Chapter 11 Diagnostic LEDs ...
Page 161: ......
Page 162: ......
Page 172: ...15 10 Chapter 15 BIOS Settings ...
Page 178: ...16 6 Chapter 16 Converting the MSR to MagTek Emulation Mode ...
Page 180: ...A 2 Appendix A Memory Map ...
Page 182: ...B 2 Appendix B IRQ Settings ...