Model 6700 Family User’s Manual
17
The Configuration
(CONF)
Mode menu allows
scale configuration for your specific application
needs. The items you can configure are as
follows:
FILTERING (FILT)
– Choose between
FAST
and
SLO
filtering.
SLO
should be chosen in areas
susceptible to vibration. Choose
FAST
filtering
for more stable conditions.
Baud (BAUD)
– Choose a baud and parity from
Table 2.
Protocol (PROT)
– Select the RS-232 communi-
cation protocol.
NCI
– NCI standard
ECR
– Cash register compatible
8213
– 8213 compatible (Sharp)
2250
– 2250 compatible (Swintec)
34-F
– 34-MF compatible (Sweda-Mexico)
ATT
– AT&T compatible
o4000
– Olympia Cash Register compatible
Access the Menu mode as shown in Figure 3.
1.
From the DIAG display, press the
ZERO
key
until
CONF
is displayed, or from the normal
weighing mode, move Switch 1 to the Menu
mode or the OPEN position; then press the
ZERO
key until
CONF
is displayed.
Configuration Mode
26. When you are finished, press the
ZERO
key,
until
DONE
is displayed, then press the
TEST
key to return to the top menu level…
DIAG
is displayed. Or close Switch 1 to
return to normal weighing mode.