LIST OF PARAMETERS OF UZJ3-P(RTCC) CONTROL UNIT
NAME
DEFAULT
SETTING
DESCRIPTION
PASoF
PASoF
Password is off = full access to all parameters
PASon
Password is on = restricted access to all parameters except for the
dAY on
or
dAY oF
parameters.
It is necessary to enter a password.
S1oF
60 (°C)
Relay 1 off limit = the maximum desired temperature of wash liquid
(when this value is reached, the heating element is switched off),
see in the heating function diagram.
S1on
55 (°C)
Relay 1 on limit = the temperature value at which the wash liquid
heating is switched on again
(S1on < S1oF), see in the heating function diagram.
tmr1
04.00 (min.s)
WASHING function timer. The time for which relay 2 is on = pump
on.
tmr2
00.00 (min.s)
Prepared for next function. The time for which relay 3 is on (the
relay is switched on after the tmr1 timer has elapsed.
ti on
06 00 (h min)
Time of switching on the TIME HEATING (PREHEATING) function if
the
dAY
parameter is set to
on
. Heating is then controlled by the
S1oF
and
S1on
parameters.
ti oF
16 00 (h min)
Time of switching off the TIME HEATING (PREHEATING) function if
the
dAY
parameter is set to
on
.
SEt d
Current day in
week
Current day in week (
mo, tu, we, th, Fr, SAt, Sun
). Correct setting is
important for the TIME HEATING (PREHEATING) function.
SEt t
Current time
Current time (e.g.:
14 22
(h min)). Correct setting is important for
the TIME HEATING (PREHEATING) function.
dAY oF
dAY oF
The TIME HEATING (PREHEATING) function is off. Heating is
controlled by the
S1oF
and
S1on
parameters regardless of a day in
the week and time.
dAY on
The TIME HEATING (PREHEATING) function is on. Heating is
controlled by the
S1oF
and
S1on
parameters with respect to a day
Failure status of
temperature
sensor!
The Pt100
temperature
sensor is not
connected or is
shorted.
Summary of Contents for ADS800
Page 5: ...P a g e 5 61 Fig 1 Front view of the machine 1 102 1 101 1 2 1 71 1 72 1 1...
Page 9: ...P a g e 9 61 Fig 2c detailed view of housing 2c 91 1 2c 3 2c 93 1 2c 2 2c 92 1 2b 4 2c 1...
Page 10: ...P a g e 10 61 Fig 3 Rear view of the machine 3 1 3 91 1 See Fig 3a Name plate 3 2 3 102 3a 1...
Page 18: ...P a g e 18 61 Fig 5 Basic dimensions of 001 ADS SFM800...