46 Operating the Boiler
10.7.2 Viewing Input and Output Status
To view the boiler’s input and output status, press the Back
button (
) and the Menu button (
) simultaneously for
3 seconds, and then select “2. Input/Output Status”.
Press the Up button (
) or the Down button (
) to switch
between the information items. Press the OK button (
) to
select an item and view the information.
Press the Back button (
) to return to the previous screen or
menu.
Item
Description
1. CH Switched Live Status
CH switched live input status
2. CH Thermostat Status
CH thermostat input status
3. Boiler Pump Status
Boiler pump output status
4. 3 Way Valve
3 Way valve output status
5. HTL Input Status
HTL input status
10.7 Accessing Advanced Menu Items
10.7.1 Viewing Service Information
To view the service information about the boiler, press the Back
button (
) and the Menu button (
) simultaneously for
3 seconds, and then select “1. Service Status Info”.
Press the Up button (
) or the Down button (
) to switch
between the information items. Press the OK button (
) to
select an item and view the information.
Press the Back button (
) to return to the previous screen or
menu.
Item
Description
1. Elapsed Time After Install Elapsed time since installation
2. HEX Overheat - No. of
Times
Number of times the heat
exchanger high limit stat has
activated
3. Flame Loss - No. of Times Number of times a flame loss/
misfire has occurred
4. 2nd ignition - No. of
Times
Number of second ignition
attempts
5. 3rd ignition - No. of
Times
Number of third ignition
attempts
6. 4th ignition - No. of
Times
Number of fourth ignition
attempts
7. 5th ignition - No. of
Times
Number of fifth ignition
attempts