Operating the Boiler 43
If you select DHW Schedule, you can select the certain day to
schedule the central heating modes.
Item
Description
1. 7 Day
Schedule a command for each
day of the week.
2. 5 + 2 Day
Schedule a command for
weekday and weekend.
3. 5 + 1 + 1 Day
Schedule a command for
weekdays, Saturdays, and
Sundays.
4. OFF (Not Used)
Disable the schedule function.
Set the DHW Schedule
When setting up the DHW option, select ‘Weekly,’ and select
between 1 Day, 3 Day, and 7 Day to go to the Schedule menu.
Working
Not working
Press the Up button (
) or the Down button (
) to choose
the scheduled time. You can choose the time in 30 minutes
intervals.
DHW Preheat - None ECO Mode
Item
Description
1. Always ON
Always DHW Preheat
10.6.4 Setting the Schedule Programming
To set the boiler’s schedule programming operation, press the
Menu button (
), and then select “4. Schedule Programming”.
10.6.3 Setting the DHW Operation
To set the boiler’s DHW operation, press the Menu button (
),
and then select “3. DHW Operation”.
Press the Up button (
) or the Down button (
) to switch
between the list items or to increase/decrease setting values.
Press the OK button (
) to select an item or to confirm after
making changes.
Press the Back button (
) to return to the previous screen or
menu.
Item
Description
1. DHW Set Temp
Set the DHW temperature.
●
Setting range: 30 – 65°C
●
Default: 50°C
2. DHW Preheat
Activate the DHW preheat
function.
Note
●
If the DHW
preheat function
is activated by the
room controller,
“RC Connected”
will be displayed.
●
The DHW preheat
function cannot
be activated, when
the Heat Demand
function is set to
OpenTherm.
DHW Preheat - ECO Mode
Item
Description
1. OFF
Do not DHW Preheat
2. DHW_Intelligent
Set to dectect DHW usage for
repeat the detected cycle
3. DHW Schedule
Set to dectect DHW usage for
a week