18 Installing the Boiler
Clearance from:
Indoor Installation
Top
250 mm minimum
Front
600 mm minimum
Bottom
200 mm minimum
Sides
5 mm minimum
Clean, debris and chemical-free combustion air
●
Do not install the boiler in areas where dust and debris may
accumulate or where hair sprays, spray detergents, chlorine,
or similar chemicals are used.
●
Do not install the boiler in areas where petrol or other
flammables are used or stored.
●
Ensure that combustible materials are stored away from
the boiler and that hanging laundry or similar items do not
obstruct access to the boiler or its flue system.
Adequate installation clearances
CAUTION
Do not install the boiler on carpeting.
Install the boiler in an area that allows for service and
maintenance access to utility connections, piping, filters,
and traps. Based on the installation location, ensure that the
following clearances are maintained:
Top
Bottom
Front
Sides
Sides