Operating the Boiler 41
Item
Description
8. Inlet Temp
Inlet temperature (°C)
9. DHW Temp
DHW temperature (°C)
10. Water Flow
Water flow rate (LPM)
11. Water Press
Water pressure (bar)
12. Flame Value
Flame detector AD value
●
Flame On: 8bit AD values
equal to or lower than 70
●
Flame Off: 8bit AD values
equal to or higher than 175
13. Fan Target RPM
Fan target speed (RPM)
14. Fan Current RPM
Fan speed (RPM)
15. Exhaust Temp
Exhaust temperature (°C)
16. OTC ON/OFF
OTC status (Enabled/Disable)
17. K-Factor Set Value
K-Factor set value
18. Model
Model type
20. Type
Boiler type (Combi/System)
21. Gas
Fuel Type (LNG G20/LPG G30/
LPG G31)
22. Main F/W Ver
Main firmware version
23. Panel F/W Ver
Panel firmware version
Note
The fan motor controls the APS, so the fan target
speed (Fan Target RPM) is only for your reference.
10.6 Accessing Basic Menu Items
In the Main Menu screen, you can view the boiler’s operating
conditions, configure the central heating and DHW
temperatures, and review error history. Press the Menu button
(
) to enter the Main Menu screen.
10.6.1 Viewing Basic Information
To view information about the boiler, press the Menu button
(
), and then select “1. Status Information”.
Press the Up button ( ) or the Down button ( ) to switch
between the information items. Press the OK button (
) to
select an item and view the information.
Press the Back button (
) to exit information view mode.
Item
Description
1. Operation State
Current Operation State
2. Heat Capacity
Heat capacity (%)
3. CH Set Temp
Central heating set temperature
(°C)
4. DHW Set Temp
DHW set temperature (°C)
5. Supply Temp
Heating supply temperature
(°C)
6. Return Temp
Boiler return temperature (°C)
7. Outdoor Temp
Outdoor temperature (°C)