56 Operating the Boiler
11.4.1 Quick Setup Menu
The Quick Setup Menu is designed to help configure the boiler
settings after installation is complete. To enter the Quick Setup
Menu, press the Menu button (
), and select “1.Quick Setup
Menu”.
Press the Back button (
) to return to the previous screen.
Item
Description
1. OTC ON/OFF
Set the outdoor temperature
compensation control settings.
1-1 K-Factor
Set the K-factor value.
1-2 WWSD Temp
Set the WWSD temperature.
2. DHW ON/OFF
Set the DHW operation.
3. DHW Call Signal
(System/Regular
Boiler Only)
Set the demand type for the DHW
operation.
4. Time Setting
Set the system clock (RTC).
Ɣ
Display format: YYYY.MM.DD/
HH:MM:SS
11.4.2 Viewing Basic Information
To view information about the boiler, press the Menu button
(
), and then select “2. Status Information”.
Rotate the Command dial (
) to switch between the
information items. Press the Command dial (
) to select an
item and view the information.
Press the Back button (
) to exit information view mode.
11.3.3 Resetting the Boiler
If an error message appears during boiler operation, reset the
boiler to resolve the problem. Press the Back button (
) on the
front panel to reset the boiler.
If resetting the boiler does not solve the problem, refer to the
Troubleshooting section of this manual or contact Technical
Support at 0844 332 2323.
11.4 Accessing Basic Menu Items
In the Main Menu screen, you can view the boiler’s operating
conditions, configure the central heating and DHW temperatures,
and review error history. Press the Menu button (
) to enter the
Main Menu screen.
Summary of Contents for LCB700-21RS
Page 78: ...78 Appendices 13 2 2 Burner Cover Flame Tube...
Page 92: ...Memo...
Page 93: ...Memo...
Page 94: ...Memo...
Page 95: ......