44
Condition/Problem
Things to Check
Solution
Check magnet position
UHTXLUHVVKURXGUHPRYDO
Magnets should be in place on pulley.
Check Speed Sensor
UHTXLUHVVKURXGUHPRYDO
Speed sensor should be aligned with magnets and connected
to data cable. Realign sensor if necessary. Replace if there is
any damage to the sensor or the connecting wire.
Resistance does not
change (machine turns on
and operates)
%DWWHULHVLIHTXLSSHG
Replace batteries and check for proper operation.
Check Console
Check for visual sign that Console is damaged. Replace Con-
sole if damaged.
Check data cable integrity All wires in cable should be intact. If any are visibly crimped or
cut, replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely and oriented properly.
Reseat all connections. Small latch on connector should line up
and snap into place.
If the above steps do not resolve the problem, contact Cus-
tomer Service (if inside US/Canada) or your local distributor (if
outside US/Canada).
&RQVROHVKXWVRႇHQWHUV
sleep mode) while in use
Check electrical (wall)
outlet
Make sure unit is plugged into a functioning wall outlet.
Check connection at front
of unit
Connection should be secure and undamaged. Replace power
cord or connection at unit if either are damaged.
Check data cable integrity All wires in the cable should be intact. If any are cut or crimped,
replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely and oriented properly.
Small latch on connector should line up and snap into place.
Reset machine
Unplug unit from electrical outlet for 3 minutes. Reconnect to
outlet.
Check magnet position
UHTXLUHVVKURXGUHPRYDO
Magnets should be in place on pulley.
Check Speed Sensor
UHTXLUHVVKURXGUHPRYDO
Speed sensor should be aligned with magnet and connected to
data cable. Realign sensor if necessary. Replace if there is any
damage to the sensor or the connecting wire.
Fan will not turn on or will
QRWWXUQRႇ
Check data cable integrity All wires in cable should be intact. If any are cut or crimped,
replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely and oriented properly.
Small latch on connector should line up and snap into place.
Reset machine
Unplug unit from electrical outlet for 3 minutes. Reconnect to
outlet.
Fan will not turn on, but
Console operates
Check for blockage of fan
Unplug unit from electrical outlet for 5 minutes. Remove mate-
rial from fan. If necessary, detach the Console to help with
removal. Replace the Console if unable to remove blockage.
Unit rocks/does not sit
level
Check leveler adjustment
Adjust levelers until machine is level.
Check surface under unit
$GMXVWPHQWPD\QRWEHDEOHWRFRPSHQVDWHIRUH[WUHPHO\XQ
-
even surfaces. Move machine to level area.