Nautilus® TreadClimber®, Model TC916 Service Manual
mechanIcal ServIce
1.0 - removInG the conSole
tools needed:
• Phillips head screw driver
• 5/32 Allen bit
1-1:
Turn off the unit and unplug from the wall outlet.
1-2:
Remove Button head screws (P/N- SM24162) on
underside of the handles on each side (see Figure 1-1).
1-3:
Gently pull console off evenly from both sides until
cables are exposed (see Figure 1-2).
1-4:
Disconnect the 2 cables on the left side
(see Figure 1-3).
1-5:
Disconnect the 1 cable on the right side
(see Figure 1-4).
NOTE:
To replace console, reverse instructions.
figure 1-1
figure 1-2
figure 1-3
figure 1-4
to Avoid electricAl shock or
dAmAge to the unit you must
power off the unit And mAke
sure All power hAs been drAined
from the unit And cApAcitors by
ensuring there Are no lighted
leds on the console.