3.0 - removInG rear Step
tools needed:
• Phillips head screw driver
• 5/32 Allen bit
3-1:
Unplug the unit from the power source and ensure
that all power has been drained from the unit.
3-2:
Remove two (2) middle screws from Rear Step Cover
(see Figure 3-1).
3-4:
Lift and slide step cover plate back to remove
(see Figure 3-2).
3-3:
Remove four (4) screws from Step Weldment (see
Figure 3-3).
3-5:
Replace rear cover by sliding back into place and re-
installing four (4) outer screws.
3-6:
Place Step cover onto Step weldment and reattach
with two (2) screws (see Figure 3-2 and Figure 3-1).
Removing the step cover plate provides access to the I/O
cables needed for the removal of the uprights.
to Avoid electricAl shock or dAmAge
to the unit you must power off the
unit And mAke sure All power hAs been
drAined from the unit And cApAcitors by
ensuring there Are no lighted leds on
the console.
7! 2 . ) . '
! 4 4 % . 4 ) / .
$ ! . ' % 2
)--%$)!4%!#4)/.2%15)2%$
# ! 5 4 ) / .
mechanIcal ServIce
figure 3-2
figure 3-1
Two Middle Screws
figure 3-3
Four outer Screws