background image

 

 

 

-6-

F. Rear view       

 

 

 

F-1. Ventilation window :   

        Do not obstruct, allow at least 1 inch for air flow. 

  F-2. Battery terminals : 
          Connect to 12V / 24V / 48V battery or other 12V / 24V / 48V   
          power source. 
          [ + ] is positive, [ - ] is negative. Reverse polarity connection will   
     blow internal fuse and may damage inverter permanently.     
 F-3. RS-485 
          Connect to remote control unit (option accessory) or taken     
      remote controlled working status by computer.             
  F-4. Chassis ground or to vehicle chassis using # 8 AWG wire. 
 

 

 

 

 

 
 
 
 
 
 
 

                               

WARNING! 

      Shock Hazard. Before proceeding Further, ensure that 
      the Inverter is NOT connected to any Batteries, and that   

all wiring is Disconnected from any electrical Sources. 
Do not connect the output Terminals of the Inverter to   
an incoming AC sources.     

                               

WARNING! 

      Operation of the inverter without a proper ground   

                 connection may result in an electrical safety hazard. 

 

 

Summary of Contents for PM-0600H

Page 1: ...High Frequency Pure Sine Wave Inverter User Manual MODEL PM 0600H PM 1000H PM 1500H PM 2000H PM 3000H ...

Page 2: ...sive Gas Precautions 1 C Precautions When Working With Batteries 1 FEATURES 2 D Introduction 2 E Name and main function 4 F Rear view 5 G Quick hook up and testing 6 H Installation 7 I Operation 9 J Operating limits 11 K Trouble shooting 12 L Maintenance 13 Appendix A 14 ...

Page 3: ...utions This equipment contains components which can produce arcs or Sparks To Prevent fire or explosion do not install in compartments containing batteries or Flammable materials or in locations which require ignition protected equipment This includes any space containing gasoline powered machinery fuel tanks or joints fittings or other connection between components of the fuel system C Precaution...

Page 4: ...olutely accurate and stable frequency z Switch selectable 50 or 60 Hz output all models z Very low harmonic distortion THD 3 z Standard inputs 12V 24V 48V z Standard outputs 110V 220V 50 60Hz z Remote control unit optional extra z Power Saving z Panel indicators for battery voltage load level z Compact and light weight yet rugged and vehicle rated 83 90 efficient z Built in fast acting AC synchron...

Page 5: ... 4 ...

Page 6: ...enable OVER VOLT Over Voltage Protection UNDER VOLT Under Voltage Protection OVER TEMP Over Temperature Protection OVER LOAD Over Load Protection INPUT VOLTS Display Input Voltage LOAD WATTS Displays AC Load Watts E 1 3 AC outlet Outlet sockets available North America GFCI North America Continental European Schuko Australia New Zealand United Kingdom Universal Socket ...

Page 7: ...o remote control unit option accessory or taken remote controlled working status by computer F 4 Chassis ground or to vehicle chassis using 8 AWG wire WARNING Shock Hazard Before proceeding Further ensure that the Inverter is NOT connected to any Batteries and that all wiring is Disconnected from any electrical Sources Do not connect the output Terminals of the Inverter to an incoming AC sources W...

Page 8: ...eck that cable you have just connects from the negative terminal of inverter to the gative output terminal of power source G 4 Connect the cable from the positive terminal of inverter to the positive terminal of the power source Make secure connection WARNING You may observe a spark when you make this connection since current may flow to charge capacitors in the power inverter Do not make this con...

Page 9: ...rn the test load on the inverter should supply power to the load If you plan to measure the true output r m s Voltage of inverter the meter such as FLUKE 45 BACKMAN 4410 or TRIPLETT 4200 must be used H Installation H 1 Where to install The power inverter should be installed in a location that meets the following requirements H 1 1 Dry Do not allow water to drip or splash on the inverter H 1 2 Col ...

Page 10: ... will damage the Inverter H 2 AC safety Grounding During the AC wiring installation AC input and output ground wires are connected to the inverter The AC input ground wire must connect to the incoming ground from your AC utility source The AC output ground wire should go to the grounding point for your loads for example a distribution panel ground bus H 2 1 Neutral Grounding H 2 1 1 120V models Th...

Page 11: ...th American approvals will require GFCI protection of all branch circuit connected to the AC output of the hardwire terminal equipped Inverter In addition electrical codes require GFCI protection of certain receptacles in residential installations While the true sine wave output of the Inverter is equivalent to the waveform provided by utilities compliance with UL standards requires us to test and...

Page 12: ...inverter turn it on using the ON OFF switch on the front panel The power inverter is now ready to deliver AC power to your loads If you are operating several loads from the power inverter turn them on separately after the inverter has been turned on This will ensure that the power inverter does not have to deliver the starting currents for all the loads at once I 1 Controls and indicators The ON O...

Page 13: ...may shut down I 3 Load watt indicator The AC load watt bar graph indicates the power drawn from the power inverter It will indicate watt by loads For long term operation the watt should in the green orange area of the bar graph Short term operation is possible with watt in the red area If the watt rises to the flash all bar the inverter will protect itself I 4 Over voltage indicator The over volta...

Page 14: ...e inverter will operate most AC loads within its power rating When deeming whether a microwave over can be operated by the inverter remember that the power commonly advertised for microwave ovens is the cooking power the power delivered to the food not the power actually consumed by the microwave oven The microwave over will consume 40 to 100 more than its advertised cooking power Check the rating...

Page 15: ...hicle boat or home Do not operate high power loads with the power inverter while watching television Make sure that the antenna feeding your television provides an adequate Snow free signal and that you are using good quality cable between the antenna and the television Move the television as far away from the power inverter as possible Keep the cables between the battery and the power inverter as...

Page 16: ...ltage Recharge battery And voltage indicator check connections In lower red zone and cable No output voltage Thermal shutdown Improve ventilation Over Temp indicator make sure ventilation On load less than openings in inverter 1500W is not obstructed reduce ambient temperature No output voltage Short circuit or Wiring Check AC wiring Over Load indicator Error For short circuit or On Improper polar...

Page 17: ...tenance is required to keep your inverter operating properly You should clean the exterior of the unit periodically with a damp cloth to regent accumulation of dust and dirt At the same time tighten the screws on the DC input terminals ...

Page 18: ...EN POWER MODE ON OFF 115V ON 50Hz ON OFF UPS MODE OFF ON 110V ON ON UPS MODE DELAY MODE GREEN POWER ON ON 100V Dip Switch 220V S1 S2 Function S3 S4 Output voltage S5 Out Frequency OFF OFF DC AC OUT MODE OFF OFF 240V OFF 60Hz OFF ON DC AC GREEN POWER MODE ON OFF 230V ON 50Hz ON OFF UPS MODE OFF ON 220V ON ON UPS MODE DELAY MODE GREEN POWER ON ON 200V ...

Page 19: ...o reduce the consummation of the Battery c UPS MODE When AC input has power the AC output power supply is by AC input so the AC Transfer is in Switch OFF condition DC AC Stand by When AC input cut off the power the AC Transfer Switch will be in 10msec from OFF ON at this time the AC output is supply by DC AC When AC input back to normal the AC Transfer Switch from ON OFF at this time the AC output...

Page 20: ...0 110 120V 2 220 230 240V 2 DIP switch select Output voltage Regulation 8 3 All models Output frequency 50 60 Hz selectable 0 05 Accuracy Output Wave form Pure Sine Wave 3 THD Efficiency Full Load 83 85 No Load power consumption 1 5W In power saving mode Input voltage range 10V 16VDC 20V 32VDC Power saving recovery time 1 second AC Transfer time UPS mode 10msec max LED status indicators High Low b...

Reviews: